Electrometric assessment of the effect of a zinc oxide paste in diaper dermatitis
Authors:
- 27 August 2009
- journal article
- Published by Wiley in International Journal of Cosmetic Science
- Vol. 31 (5) , 369-374
Abstract
Synopsis: Diaper dermatitis affects nearly 50% of infants as well as some bed‐ridden adults particularly in the elderly people. This condition is induced by irritation and maceration, and may be further exacerbated by Candida sp. colonization and infection. A key factor in the pathogenesis is the alteration in both the barrier function and the water‐holding capacity of the stratum corneum. The purpose of this study was to assess the effects of an unmedicated zinc oxide–petrolatum paste and to observe for possible shielding and restoring effects on the water‐holding capacity of the stratum corneum altered by diaper dermatitis. The paste appeared to load the hollow skin microrelief. It was inferred that this effect was responsible for a reticulated shielding effect. Compared with healthy skin and untreated diaper dermatitis, the application of the anhydrous paste resulted in a trend to normalize electrometric properties of skin reflecting the combination of transepidermal water loss and the water‐holding capacity of the stratum corneum.Keywords
This publication has 24 references indexed in Scilit:
- The stratum corneum: a double paradoxJournal of Cosmetic Dermatology, 2008
- Prevention, Diagnosis, and Management of Diaper DermatitisClinical Pediatrics, 2007
- Smoothing the mosaic subclinical melanoderma by calcipotriolJournal of the European Academy of Dermatology and Venereology, 2007
- Prospective aetiological study of diaper dermatitis in the elderlyBritish Journal of Dermatology, 2006
- Skin changes induced by a zinc oxide dressing compared with a hydrocolloid dressing in healthy individualsSkin Research and Technology, 2005
- Comparative study of five instruments measuring stratum corneum hydration (Corneometer CM 820 and CM 825, Skicon 200, Nova DPM 9003, DermaLab). Part II. In vivoSkin Research and Technology, 1999
- Non‐invasive electrical measurements for the evaluation of the hydration state of the skin: comparison between three conventional instruments ‐ the Comeometer®, the Skicon® and the Nova DPM®Skin Research and Technology, 1999
- Tribological and mycological consequences of the use of a miconazole nitrate-containing paste for the prevention of diaper dermatitis: an open pilot studyEuropean Journal of Pediatrics, 1996
- Use of Continuous Electrical Capacitance and Transepidermal Water Loss Measurements for Assessing Barrier Function in Neonatal Rat SkinSkin Pharmacology and Physiology, 1995
- EFFECTS OF SOFTFNFD AND UNSOFTFNED FABRICS ON INFANT SKINInternational Journal of Dermatology, 1994