Development and validation of a weight-bearing finite element model for total knee replacement
Authors:
- 7 October 2015
- journal article
- research article
- Published by Taylor & Francis in Computer Methods in Biomechanics and Biomedical Engineering
- Vol. 19 (10) , 1033-1045
Abstract
Total knee arthroplasty (TKA) is a successful procedure for osteoarthritis. However, some patients (19%) do have pain after surgery. A finite element model was developed based on boundary conditions of a knee rig. A 3D-model of an anatomical full leg was generated from magnetic resonance image data and a total knee prosthesis was implanted without patella resurfacing. In the finite element model, a restarting procedure was programmed in order to hold the ground reaction force constant with an adapted quadriceps muscle force during a squat from 20° to 105° of flexion. Knee rig experimental data were used to validate the numerical model in the patellofemoral and femorotibial joint. Furthermore, sensitivity analyses of Young’s modulus of the patella cartilage, posterior cruciate ligament (PCL) stiffness, and patella tendon origin were performed. Pearson’s correlations for retropatellar contact area, pressure, patella flexion, and femorotibial ap-movement were near to 1. Lowest root mean square error for retropatellar pressure, patella flexion, and femorotibial ap-movement were found for the baseline model setup with Young’s modulus of 5 MPa for patella cartilage, a downscaled PCL stiffness of 25% compared to the literature given value and an anatomical origin of the patella tendon. The results of the conducted finite element model are comparable with the experimental results. Therefore, the finite element model developed in this study can be used for further clinical investigations and will help to better understand the clinical aspects after TKA with an unresurfaced patella.Keywords
This publication has 39 references indexed in Scilit:
- Patellofemoral contact patterns before and after total knee arthroplasty: an in vitro measurementBioMedical Engineering OnLine, 2013
- Considerations for reporting finite element analysis studies in biomechanicsJournal of Biomechanics, 2012
- The effect of load magnitude on three-dimensional patellar kinematics in vivoJournal of Biomechanics, 2010
- Verification of Predicted Knee Replacement Kinematics During Simulated Gait in the Kansas Knee SimulatorJournal of Biomechanical Engineering, 2010
- Verification of predicted specimen-specific natural and implanted patellofemoral kinematics during simulated deep knee bendJournal of Biomechanics, 2009
- Simulation of force loaded knee movement in a newly developed in vitro knee simulator / Simulation von belastungsabhängigen Kniebewegungen in einem neuartigen Knie-Simulator für In-vitro-StudienBiomedical Engineering / Biomedizinische Technik, 2009
- The influence of deceleration forces on ACL strain during single-leg landing: A simulation studyJournal of Biomechanics, 2007
- A three-dimensional finite element analysis of the combined behavior of ligaments and menisci in the healthy human knee jointJournal of Biomechanics, 2006
- Why knees failThe Journal of Arthroplasty, 2003
- In vivo tracking of the human patellaJournal of Biomechanics, 1992