Imaging of high-energy x-ray emission from cryogenic thermonuclear fuel implosions on the NIF
- 18 July 2012
- journal article
- conference paper
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 83 (10) , 10E115
Abstract
Accurately assessing and optimizing the implosion performance of inertial confinement fusion capsules is a crucial step to achieving ignition on the NIF. We have applied differential filtering (matched Ross filter pairs) to provide broadband time-integrated absolute x-ray self-emission images of the imploded core of cryogenic layered implosions. This diagnostic measures the temperature- and density-sensitive bremsstrahlung emission and provides estimates of hot spot mass, mix mass, and pressure.Keywords
Funding Information
- U.S. Department of Energy (DE-AC52-07NA27344)
This publication has 10 references indexed in Scilit:
- First implosion experiments with cryogenic thermonuclear fuel on the National Ignition FacilityPlasma Physics and Controlled Fusion, 2012
- The experimental plan for cryogenic layered target implosions on the National Ignition Facility—The inertial confinement approach to fusionPhysics of Plasmas, 2011
- High-energy x-ray backlighter spectrum measurements using calibrated image platesReview of Scientific Instruments, 2011
- A hardened gated x-ray imaging diagnostic for inertial confinement fusion experiments at the National Ignition FacilityReview of Scientific Instruments, 2010
- Simulations of high-mode Rayleigh-Taylor growth in NIF ignition capsulesJournal of Physics: Conference Series, 2008
- Gated x-ray detector for the National Ignition FacilityReview of Scientific Instruments, 2006
- The National Ignition Facility: enabling fusion ignition for the 21st centuryNuclear Fusion, 2004
- The Physics of Inertial Fusion2004
- Laser Compression of Matter to Super-High Densities: Thermonuclear (CTR) ApplicationsNature, 1972
- Minutes of the Oakland Meeting, June 17, 1926Physical Review B, 1926