Evaluation of the Position and Function of Aqueous Drainage Implants With Magnetic Resonance Imaging
Authors:
- Efstathios T. DetorakisEDEfstathios T. Detorakis
- Thomas MarisTMThomas Maris
- Efrosini PapadakiEPEfrosini Papadaki
- Miltiadis K. TsilimbarisMTMiltiadis K. Tsilimbaris
- Apostolos H. KarantanasAKApostolos H. Karantanas
- Ioannis G. PallikarisIPIoannis G. Pallikaris
- 1 August 2009
- journal article
- Published by Wolters Kluwer Health in Journal of Glaucoma
- Vol. 18 (6) , 453-459
Abstract
To evaluate position and function of antiglaucomatous Ahmed and Molteno shunts using magnetic resonance imaging with head and surface coils. Eight patients (5 males) with shunt implants were included, 4 with Ahmed (FP-7) and 4 with Molteno (s1, single plated). All patients were operated at least 6 months before imaging. In 3 cases (2 with Molteno and 1 with Ahmed shunt), the intraocular pressure (IOP) was above 21 mm Hg, despite maximal medical treatment. The shunt endplate, tube and filtering blebs were identified in T1-weighted and T2-weighted images with both head and surface coils. Volumetric measurements of the orbits, eyeball, and filtering bleb and calculation of the endplate position along sagittal, transverse, and vertical axes were performed in T1-weighted and T2-weighted images using head coils. The shunt endplate was identified in T1-weighted and T2-weighted images (head coils) as a low intensity (dark) circumlinear band at the superotemporal aspect of the eyeball, surrounded by a pocket of water density, corresponding to the filtering bleb. The anterior position of the endplate, and smaller volume of the orbital cavity (less available orbital space) were associated with higher IOP. Filtering bleb volume was inversely correlated with IOP. In the unsuccessful cases, filtering bleb was absent. Magnetic resonance imaging provides insights into the mechanism of aqueous outflow and causes of failure of shunts. A lower orbital volume is associated with anterior position of the shunt endplate and poor shunt performance.Keywords
This publication has 22 references indexed in Scilit:
- MR Imaging Features of Giant Reservoir Formation in the Orbit: An Unusual Complication of Ahmed Glaucoma Valve ImplantationAmerican Journal of Neuroradiology, 2007
- Ahmed Glaucoma Valve Implants in the Pediatric Population: The Use of Magnetic Resonance Imaging Findings for Surgical Approach to ReoperationJournal of American Association for Pediatric Ophthalmology and Strabismus, 2006
- CSF Flow Quantification of the Cerebral Aqueduct in Normal Volunteers Using Phase Contrast Cine MR ImagingKorean Journal of Radiology, 2004
- Functional Anatomy of the Anophthalmic Socket: Insights from Magnetic Resonance ImagingInvestigative Ophthalmology & Visual Science, 2003
- Peritubular filtration as cause of severe hypotony after Ahmed valve implantation for glaucomaAmerican Journal of Ophthalmology, 2001
- ANOPHTHALMIC SOCKET AND ORBITAL IMPLANTSRadiologic Clinics of North America, 1998
- A clinical study of the Ahmed glaucoma valve implant in advanced glaucomaOphthalmology, 1998
- Initial Clinical Experience with the Baerveldt Implant in Complicated GlaucomasOphthalmology, 1994
- Glaucoma drainage implantsCurrent Opinion in Ophthalmology, 1994
- New implant for drainage in glaucoma. Clinical trial.British Journal of Ophthalmology, 1969