Simultaneous estimation of muscle fibre conduction velocity and muscle fibre orientation using 2D multichannel surface electromyogram
Authors:
- 1 February 2005
- journal article
- research article
- Published by Springer Nature in Medical & Biological Engineering & Computing
- Vol. 43 (1) , 63-70
Abstract
The paper presents a new approach for simultaneous estimation of muscle fibre conduction velocity (MFCV) and muscle fibre orientation (MFO) for motor units (MUs) in two-dimensional (2D) multichannel surface electromyography recordings. This is an important tool for detecting changes and abnormalities in muscle function and structure. In addition, simultaneous estimation of MFO and MFCV avoids the necessity of manual electrode alignment. The proposed method detected propagating MU action potentials (MUAPs) in a running time window as moving components in amplitude maps. Thereafter, estimations were obtained by fitting a three-dimensional function to these maps. The performance was evaluated using synthetic MU signals at 10 dB SNR and authentic biceps brachii measurements. Results demonstrated MFCV and MFO estimates with standard deviations of less than 0.05 m s−1 and 1° for simulated signals, and less than 0.2 m s−1 and 4° for experimental data. However, standard deviations as low as 0.12 m s−1 and 1.6° from real signals were demonstrated. It was concluded that the method performs as well as, or better than, linear array multichannel methods when individual propagating MUAPs can be identified, even if electrodes are not aligned with fibre direction.Keywords
This publication has 29 references indexed in Scilit:
- Reproducibility of muscle‐fiber conduction velocity estimates using multichannel surface EMG techniquesMuscle & Nerve, 2004
- Muscle‐fiber conduction velocity and electromyography as diagnostic tools in patients with suspected inflammatory myopathy: A prospective studyMuscle & Nerve, 2003
- A novel approach for precise simulation of the EMG signal detected by surface electrodesIEEE Transactions on Biomedical Engineering, 2001
- Diagnostic value of in situ muscle fiber conduction velocity measurements in myopathiesActa Neurologica Scandinavica, 1996
- Long‐lasting supernormal conduction velocity after sustained maximal isometric contraction in human muscleMuscle & Nerve, 1993
- Fibre conduction velocity and fibre composition in human vastus lateralisEuropean Journal of Applied Physiology, 1988
- An Iterative Technique for Absolute Deviations Curve FittingJournal of the American Statistical Association, 1973
- L 1 Approximation and the Analysis of DataJournal of the Royal Statistical Society Series C: Applied Statistics, 1968
- Conduction Velocity and Amplitude of the Action Potential as Related to Circumference in the Isolated Fibre of Frog MuscleActa Physiologica Scandinavica, 1956
- XXII. On a new method of reducing observations relating to several quantitiesJournal of Computers in Education, 1888