Coagulation assessment by rotation thrombelastometry in normal pregnancy
Authors:
- 1 January 2009
- journal article
- research article
- Published by Georg Thieme Verlag KG in Thrombosis and Haemostasis
- Vol. 101 (04) , 755-761
Abstract
We analysed changes in coagulation during normal pregnancy with a novel point-of-care device based on thrombelastometry (ROTEM®). We compared the results obtained with those of standard coagulation tests in 104 patients: 20 non-pregnant women (controls) and 84 women in the first (T1, n=17), second (T2, n=9) and third (T3, n=58) trimesters of pregnancy. We measured the clotting time (CT), the maximum clot firmness (MCF), the early clot amplitude at 5 and 15 minutes (CA5, CA15) and the clot lysis index (CLI30) with four tests containing specific reagents. (a) The INTEM® test involving ellagic acid activated the intrinsic pathway and (b) the EXTEM® test using tissue factor triggered the extrinsic pathway; (c) The FIBTEM® test based on a platelet inhibitor (cytochalasin D) evaluated the contribution of fibrinogen to clot formation and (d) the APTEM® test was similar to the EXTEM but was based on inhibition in vitro of fibrinolysis by aprotinin. CT and CLI30 were not significantly modified during pregnancy whereas MCF, CA5 and CA15 (INTEM, EXTEM, FIBTEM) increased significantly between the second and third trimesters (e.g. median [interquartile range]: MCF-FIBTEM, 13 [11–16] mm vs. 19 [17–23] mm, respectively, in controls and T3, p< 0.001). EXTEM values were not significantly different from those measured with APTEM. There were significant correlations between the results obtained with ROTEM and those from standard coagulation tests. ROTEM analysis showed a marked increase in coagulability during normal pregnancy. ROTEM values may serve as the basis for future studies in pregnant women.Keywords
This publication has 18 references indexed in Scilit:
- Diagnosis of early coagulation abnormalities in trauma patients by rotation thrombelastographyJournal of Thrombosis and Haemostasis, 2007
- New approaches for measuring coagulationHaemophilia, 2006
- A direct thrombin inhibitor studied by dynamic whole blood clot formationThrombosis and Haemostasis, 2006
- Haemostasis in normal pregnancy: a balancing act?Biochemical Society Transactions, 2005
- Thrombelastography/thromboelastometryClinical and Laboratory Haematology, 2005
- In vitro comparison of the effect of fondaparinux and enoxaparin on whole blood tissue factor-triggered thromboelastography profileThrombosis and Haemostasis, 2004
- ThrombelastographyBlood Coagulation & Fibrinolysis, 2001
- Coagulation and Fibrinolytic Parameters in Normal Pregnancy and in Pregnancy Complicated by Intrauterine Growth RetardationAmerican Journal of Perinatology, 1998
- Venous Thromboembolism during PregnancyNew England Journal of Medicine, 1996
- Thromboelastography and sonoclot analysis in the healthy parturientJournal of Clinical Anesthesia, 1993