Application of the Willis Covered Stent in the Treatment of Complex Vascular Diseases of the Internal Carotid Artery and Vertebral Artery: A Retrospective Single-Center Experience
Authors:
Open Access
- 1 September 2023
- journal article
- research article
- Published by Taylor & Francis in Therapeutics and Clinical Risk Management
- Vol. ume 19, 773-782
Abstract
Objective: To retrospectively evaluate the efficacy and security of Willis covered stent (WCS) deployment for complex vascular diseases of the internal carotid (ICA) and vertebral (VA) arteries. Methods: Retrospective analysis was performed on complex vascular disease patients (n=36) treated with WCSs at our center between March 2017 and December 2022, with a 3– 36-months follow-up surveillance and digital subtraction angiography (DSA) examination. Results: The WCSs were successfully deployed in all the patients. The 36 included lesions were carotid-cavernous sinus fistulas (CCFs; n=10) (27.8%), complex saccular aneurysms (n=10) (27.8%), traumatic pseudoaneurysms (n=7) (19.4%), blood blister-like aneurysms (BBAs; n=5) (13.9%), and iatrogenic carotid or vertebral artery ruptures (n=4) (11.1%). The WCS was released at the communicating segment (n=2) (5.6%), the ophthalmic segment (n=3) (8.3%), the clinoid and cavernous segment (n=28) (77.8%), the petrous segment (n=2) (5.6%) of ICA and the V3 segment (n=1) (2.8%) of VA. Postoperative DSA showed complete lesion occlusion in 26 patients (72.2%) who were immediately treated with WCSs, and endoleaks occurred in 3 patients (8.3%) (endoleaks resolved postadjustment in 7 patients (19.4%)). In patients (n=3) (8.3%) treated with double stents at the break of the ICA, the endoleak remained in 1 CCF patient (2.8%) during the 3-month follow-up, and the residual shunt disappeared after the second stent system was placed 3 months later. No aneurysm, bleeding or infarct recurrence reported, and only 1 patient (2.8%) had mild asymptomatic in-stent stenosis. Deaths and procedural complications did not occur during follow-up. Conclusion: Treatment with a WCS for intracranial complex vascular diseases resulted in satisfactory clinical outcomes and appeared effective and safe. Controlled, multicenter, large sample sizes and longer follow-up periods studies are necessary.Keywords
This publication has 22 references indexed in Scilit:
- Implication of the inferolateral trunk of the cavernous internal CAROTID artery in cranial nerve blood supply: Anatomical study and review of the literatureAnnals of Anatomy - Anatomischer Anzeiger, 2019
- Endovascular intervention of acute ischemic stroke due to occlusion of fetal posterior cerebral arteryInterventional Neuroradiology, 2018
- Endovascular coiling versus neurosurgical clipping for people with aneurysmal subarachnoid haemorrhageCochrane Database of Systematic Reviews, 2018
- Complications of endovascular treatment for intracranial aneurysms: Management and preventionInterventional Neuroradiology, 2018
- Endovascular treatment of ruptured blood blister-like aneurysms with multiple (≥3) overlapping Enterprise stents and coilingActa Neurochirurgica, 2016
- The durability of endovascular coiling versus neurosurgical clipping of ruptured cerebral aneurysms: 18 year follow-up of the UK cohort of the International Subarachnoid Aneurysm Trial (ISAT)The Lancet, 2015
- Frequency and predictors of endoleaks and long-term patency after covered stent placement for the treatment of intracranial aneurysms: a prospective, non-randomised multicentre experienceEuropean Radiology, 2012
- Endovascular Reconstruction with the Willis Covered Stent for the Treatment of Large or Giant Intracranial AneurysmsCerebrovascular Diseases, 2010
- A New Covered Stent Designed for Intracranial Vasculature: Application in the Management of Pseudoaneurysms of the Cranial Internal Carotid ArteryAmerican Journal of Neuroradiology, 2007
- Patterns and Mechanisms of In-Stent RestenosisCirculation, 1996