Early Patency Evaluation of New Distal Anastomotic Device in Internal Mammary Artery Grafts Using Computed Tomography Angiography
Authors:
Open Access
- 1 March 2010
- journal article
- research article
- Published by SAGE Publications in Innovations: Technology and Techniques in Cardiothoracic and Vascular Surgery
- Vol. 5 (2) , 109-113
Abstract
Introduction: Traditional coronary artery bypass grafting is performed using a hand sewn technique. The C-Port xA and Flex A anastomotic stapling devices (Cardica Inc., Redwood City, CA) were cleared by the Food and Drug Administration for use in distal coronary anastomoses in November 2006 and April 2007, respectively. They provide the ability to create a compliant, consistently reproducible, and automated anastomosis. Multidetector computed tomography (CT) has been shown to be effective in evaluating coronary artery bypass graft patency. Methods: The first 24 patients to undergo internal mammary artery (IMA) anastomosis using the automated device in our practice were included in the study. Twenty-five IMA grafts (24 left IMA and 1 right IMA) were created using the C-Port xA or Flex A anastomotic device as part of multivessel off-pump coronary revascularization by sternotomy. Graft patency was evaluated at 30 days in the first 10 grafts and at 90 days in the next 15 grafts using multidetector (64 slice) CT. Results: There were no device failures. There were no perioperative strokes, myocardial infarctions, or deaths. All 10 IMA grafts evaluated at 30 days were patent using multidetector CT. One of the 15 IMA grafts studied at 90 days was occluded using multidetector computed tomography. Conclusions: The C-Port xA and Flex A distal anastomotic devices provided a safe and effective means to create a left IMA-left anterior descending artery anastomoses in coronary bypass surgery with excellent short to midterm patency in this early experience. Long-term follow-up is warranted. These findings will have important implications for future sternal sparing coronary bypass surgery.Keywords
This publication has 15 references indexed in Scilit:
- Diagnostic Performance of 16- and 64-Section Spiral CT for Coronary Artery Bypass Graft Assessment: Meta-AnalysisRadiology, 2008
- Sixteen-Slice Multidetector Computed Tomography for Graft Patency Evaluation After Coronary Artery Bypass SurgeryJournal of Cardiac Surgery, 2008
- Prospective Evaluation of Patency and Early Experience Utilizing an Automated Distal Anastomosis Device (C-Port)Innovations: Technology and Techniques in Cardiothoracic and Vascular Surgery, 2007
- Long-Term Results After Systematic Off-Pump Coronary Artery Bypass Graft Surgery in 1000 Consecutive PatientsCirculation, 2006
- The Cardica C-Port System: Clinical and angiographic evaluation of a new device for automated, compliant distal anastomoses in coronary artery bypass grafting surgery—A multicenter prospective clinical trialThe Journal of Thoracic and Cardiovascular Surgery, 2005
- Anastomotic devices for coronary artery bypass graftingExpert Review of Medical Devices, 2005
- Multidetector Computed Tomography Versus Coronary Angiogram in Evaluation of Coronary Artery Bypass GraftsThe Annals of Thoracic Surgery, 2005
- Hemodynamic Changes During Posterior Vessel Off-Pump Coronary Artery Bypass: Comparison Between Deep Pericardial Sutures and Vacuum-Assisted Apical Suction DeviceThe Annals of Thoracic Surgery, 2004
- Coronary bypass graft fate: Long-term angiographic studyJACC, 1991
- Influence of the Internal-Mammary-Artery Graft on 10-Year Survival and Other Cardiac EventsNew England Journal of Medicine, 1986