Biological Immunoassays Without Bound/Free Separation Utilizing Magnetic Marker and HTS SQUID
Authors:
- K. EnpukuKEK. Enpuku
- K. SoejimaKSK. Soejima
- T. NishimotoTNT. Nishimoto
- T. MatsudaTMT. Matsuda
- H. TokumitsuHTH. Tokumitsu
- T. TanakaTTT. Tanaka
- K. YoshinagaKYK. Yoshinaga
- H. KumaHKH. Kuma
- N. HamasakiNHN. Hamasaki
- 23 July 2007
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 17 (2) , 816-819
Abstract
We have developed a magnetic immunoassay system utilizing a magnetic marker and HTS SQUID. In this system, the magnetic marker was used to detect the biological material called antigen. The magnetic marker was designed so as to generate a remanence, and the remanence field of the markers that bound to the antigens was measured with the SQUID. The measurement was performed in a solution that contained both the bound and free (or unbound) markers, i.e., without using the so-called bound/free (BF) separation process. The Brownian rotation of the free markers in the solution was used to distinguish the bound markers from the free ones. Using the system, we conducted the detection of the biological material called human IgE. Good relationship was obtained between the detected signal and the weight of IgE. Minimum detectable weight of IgE was 2.4 pg (or 15 atto-mol). This sensitivity was limited by the background signal from the free markers.Keywords
This publication has 11 references indexed in Scilit:
- Liquid phase immunoassay utilizing magnetic marker and high Tc superconducting quantum interference deviceJournal of Applied Physics, 2006
- Magnetic relaxation measurement in immunoassay using high-transition-temperature superconducting quantum interference device systemJournal of Applied Physics, 2006
- Development of Multisample Biological Immunoassay System Using HTS SQUID and Magnetic NanoparticlesIEEE Transactions on Applied Superconductivity, 2005
- Magnetic Immunoassays Utilizing Magnetic Markers and a High-$T_rm c$SQUIDIEEE Transactions on Applied Superconductivity, 2005
- Biological sensing with magnetic nanoparticles using Brownian relaxation (invited)Journal of Applied Physics, 2005
- Magnetic Marker and High Tc Superconducting Quantum Interference Device for Biological ImmunoassaysIEICE Transactions on Electronics, 2005
- Binding kinetics of magnetic nanoparticles on latex beads studied by magnetorelaxometryApplied Organometallic Chemistry, 2004
- Detection of bacteria in suspension by using a superconducting quantum interference deviceProceedings of the National Academy of Sciences, 2003
- Magnetorelaxometry—a new binding specific detection method based on magnetic nanoparticlesJournal of Magnetism and Magnetic Materials, 2002
- Ultrasensitive magnetic biosensor for homogeneous immunoassayProceedings of the National Academy of Sciences, 2000