Abstract
Assemblies of hollow capillary tubes, termed ‘‘Kumakhov optics,’’ can be used to control x rays for a large variety of applications. Measurements of x-ray transmission in polycapillary glass tubes were performed for the purpose of understanding their behavior in such devices. X-ray transmission was measured for straight, uniformly curved, and nonuniformly bent fibers. The data agree well with a computer simulation based on classical ray tracing.Keywords
This publication has 6 references indexed in Scilit:
- A polycapillary-based X-ray optical system for diffraction applicationsNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1993
- X-Ray Interactions: Photoabsorption, Scattering, Transmission, and Reflection at E = 50-30,000 eV, Z = 1-92Atomic Data and Nuclear Data Tables, 1993
- Channeling of photons and new X-ray opticsNuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms, 1990
- Focusing of synchrotron radiation using tapered glass capillariesPhysica B: Condensed Matter, 1989
- Wide-band x-ray optics with a large angular apertureSoviet Physics Uspekhi, 1989
- The renaissance of x-ray opticsPhysics Today, 1984