Integrated Device for Cancer Nucleic Acid Biomarker Detection at Body Temperature
Open Access
- 7 February 2025
- journal article
- research article
- Published by MDPI AG in Micromachines
- Vol. 16 (2) , 192
Abstract
The quantitative analysis of nucleic acid markers is extensively utilized in cancer detection. However, it faces significant challenges, such as the need for specialized detection devices and the inherent complexity of testing procedures. To address these issues, this study proposes a simplified, rapid, and user-friendly platform for cancer nucleic acid marker detection. We firstly designed a polydimethylsiloxane (PDMS) device for the isothermal amplification reaction of nucleic acid biomarkers based on reverse-transcription recombinase-aided amplification (RT-RAA) technology. Specifically, three potential cancer nucleic acid biomarkers, carcinoembryonic antigen (CEA), prostate-specific antigen (PSA), and prostate cancer antigen 3 (PCA3) were amplified from human serum or urine samples in the PDMS device at body temperature. The reaction chamber was directly integrated with nucleic acid test strips labeled with colloidal gold nanoparticles, allowing for the visual observation of the detection results for the amplification products. The optimal reaction conditions, such as pH, reaction time, antibody, and streptavidin concentration, were defined after a series of optimization studies. The findings demonstrated that the optimal RT-RAA reaction time was 20 min, the primary antibodies were labeled with colloidal gold to the greatest extent at pH 8.5, and the optimal concentrations of secondary antibody and streptavidin were 1.0 mg/mL and 0.5 mg/mL, respectively. Furthermore, this novel detection approach could not only exhibit excellent sensitivity and specificity but also show high accuracy for the analysis of nucleic acid biomarkers in both clinical serum and urine samples. Therefore, the simplified and more convenient operation platform provides a new insight for the semi-quantitative analysis of cancer nucleic acid biomarkers and the rapid screening of early cancer, thereby offering a promising alternative to oncological point-of-care testing (POCT) diagnostics.Keywords
Funding Information
- Dalian Key R&D Program Project (2021YF18SN023, DUT24YG127, DUT22YG215)
- Fundamental Research Funds for the Central Universities (2021YF18SN023, DUT24YG127, DUT22YG215)
- Dalian Medical-Engineering Cross Project (2021YF18SN023, DUT24YG127, DUT22YG215)
This publication has 33 references indexed in Scilit:
- Epidemiological investigation of swine Japanese encephalitis virus based on RT-RAA detection methodScientific Reports, 2022
- Rapid and sensitive detection of African swine fever virus in pork using recombinase aided amplification combined with QDMs-based test stripAnalytical and Bioanalytical Chemistry, 2022
- Rapid detection of cagA-positive Helicobacter pylori based on duplex recombinase aided amplification combined with lateral flow dipstick assayDiagnostic Microbiology and Infectious Disease, 2022
- Development of Recombinase Aided Amplification Combined With Disposable Nucleic Acid Test Strip for Rapid Detection of Porcine Circovirus Type 2Frontiers in Veterinary Science, 2021
- Development and Preliminary Application of Multiplex Loop-Mediated Isothermal Amplification Coupled With Lateral Flow Biosensor for Detection of Mycobacterium tuberculosis ComplexFrontiers in Cellular and Infection Microbiology, 2021
- Clinical Validation of Two Recombinase-Based Isothermal Amplification Assays (RPA/RAA) for the Rapid Detection of African Swine Fever VirusFrontiers in Microbiology, 2020
- Internally controlled recombinase-aided amplification (IC-RAA) assays for the detection of human papillomavirus genotypes 16 and 18 using extracted DNA and samples treated with nucleic acid releasing agentArchives of Virology, 2020
- Measurement of Carcinoembryonic Antigen in Clinical Serum Samples Using a Centrifugal Microfluidic DeviceMicromachines, 2018
- Colloidal gold-based immunochromatographic strip test compromising optimised combinations of anti-S. suis capsular polysaccharide polyclonal antibodies for detection of Streptococcus suisBiosensors and Bioelectronics, 2014
- Serum carcinoembryonic antigen level is associated with arterial stiffness in healthy Korean adultClinica Chimica Acta, 2013