Device-Less Data-Driven Cardiac and Respiratory Gating Using LAFOV PET Histo Images
Authors:
- Nanna OverbeckNONanna Overbeck
- Thomas Lund AndersenTAThomas Lund Andersen
- Anders Bertil RodellARAnders Bertil Rodell
- Jorge CabelloJCJorge Cabello
- Noah BirgeNBNoah Birge
- Paul SchleyerPSPaul Schleyer
- Maurizio ContiMCMaurizio Conti
- Kirsten KorsholmKirsten Korsholm
- Barbara Malene FischerBarbara Malene Fischer
- Flemming Littrup AndersenFAFlemming Littrup Andersen
- Ulrich LindbergULUlrich Lindberg
Open Access
- 16 September 2024
- journal article
- research article
- Published by MDPI AG in Diagnostics
- Vol. 14 (18) , 2055
Abstract
Background: The outstanding capabilities of modern Positron Emission Tomography (PET) to highlight small tumor lesions and provide pathological function assessment are at peril from image quality degradation caused by respiratory and cardiac motion. However, the advent of the long axial field-of-view (LAFOV) scanners with increased sensitivity, alongside the precise time-of-flight (TOF) of modern PET systems, enables the acquisition of ultrafast time resolution images, which can be used for estimating and correcting the cyclic motion. Methods: 0.25 s so-called [18F]FDG PET histo image series were generated in the scope of for detecting respiratory and cardiac frequency estimates applicable for performing device-less data-driven gated image reconstructions. The frequencies of the cardiac and respiratory motion were estimated for 18 patients using Short Time Fourier Transform (STFT) with 20 s and 30 s window segments, respectively. Results: The Fourier analysis provided time points usable as input to the gated reconstruction based on eight equally spaced time gates. The cardiac investigations showed estimates in accordance with the measured pulse oximeter references (p = 0.97) and a mean absolute difference of 0.4 ± 0.3 beats per minute (bpm). The respiratory frequencies were within the expected range of 10–20 respirations per minute (rpm) in 16 out of 18 patients. Using this setup, the analysis of three patients with visible lung tumors showed an increase in tumor SUVmax and a decrease in tumor volume compared to the non-gated reconstructed image. Conclusions: The method can provide signals that were applicable for gated reconstruction of both cardiac and respiratory motion, providing a potential increased diagnostic accuracy.Keywords
Funding Information
- Siemens
This publication has 40 references indexed in Scilit:
- Assessment of motion correction in dynamic rubidium-82 cardiac PET with and without frame-by-frame adjustment of attenuation maps for calculation of myocardial blood flowJournal of Nuclear Cardiology, 2021
- Series of myocardial FDG uptake requiring considerations of myocardial abnormalities in FDG-PET/CTJapanese Journal of Radiology, 2021
- The impact of data-driven respiratory gating in clinical F-18 FDG PET/CT: comparison of free breathing and deep-expiration breath-hold CT protocolAnnals of Nuclear Medicine, 2021
- Data‐driven gating in PET: Influence of respiratory signal noise on motion resolutionMedical Physics, 2018
- Evaluation of the new respiratory gating systemPrecision Radiation Oncology, 2017
- Respiratory gated PET/CT in a European multicentre retrospective study: added diagnostic value in detection and characterization of lung lesionsEuropean Journal of Nuclear Medicine and Molecular Imaging, 2012
- Focus on time-of-flight PET: the benefits of improved time resolutionEuropean Journal of Nuclear Medicine and Molecular Imaging, 2011
- Detection of respiratory tumour motion using intrinsic list mode-driven gating in positron emission tomographyEuropean Journal of Nuclear Medicine and Molecular Imaging, 2010
- The effect of 18F-FDG-PET/CT respiratory gating on detected metabolic activity in lung lesionsAnnals of Nuclear Medicine, 2009
- PET-CT in oncologyClinical and Translational Oncology, 2007