Validation of the Nordic Flow Cytometry Standard for CD34+ Cell Enumeration in Blood and Autografts: Report from the Third Workshop
Authors:
- Hans E. JohnsenHJHans E. Johnsen
- J. BaechJBJ. Baech
- K. NikolajsenKNK. Nikolajsen
- 1 February 1999
- journal article
- research article
- Published by SAGE Publications in Journal of Hematotherapy
- Vol. 8 (1) , 15-28
Abstract
Following two workshops on standardization of enumeration of CD34+ cells in blood and leukapheresis products, the Nordic Stem Cell Laboratory Group (NSCL-G) evaluated the Milan/Mulhouse/Nordic standard in clinical practice during the third workshop (WS-III). This report documents an acceptable interlaboratory variation in the most clinically active laboratories, with a coefficient of variation (CV) below 0.19 in 7 of 8 analyses performed. The introduction of a pan-CD45 antibody in the analysis did not improve the CV. Comparison of two different CD34 class II antibodies on a total of 99 samples and procedures with and without washing on a total of 96 samples revealed a significant correlation (r2 > 0.99) for all analyses. Finally, subset analysis of uncommitted and lineage-specific progenitors revealed major gating difficulties, indicating that further improvements are necessary. In an analysis of more than 600 patients undergoing mobilization and harvest of blood progenitors, with about 500 patients autografted, we found a significant correlation between blood levels of CD34+ cells and recovery of CD34+ cells from each harvest as well as between CD34+ cell number reinfused and time to neutrophil and platelet recovery. This report documents for the first time that the very simple Milan/Mulhouse method (termed The Nordic Standard) can be used by a group of laboratories to obtain important clinical information. Consequently, we consider this method as the conventional method in quality assessment of autografts, which should provide a benchmark for development of second-generation improvements.Keywords
This publication has 18 references indexed in Scilit:
- A Convergence of Methods for a Worldwide Standard for CD34+ Cell EnumerationJournal of Hematotherapy, 1998
- An Intralaboratory Quality Control Program for Quantitation of CD34+ Cells by Flow CytometryJournal of Hematotherapy, 1997
- The Influence of Flow Cytometric Gating Strategy on the Standardization of CD34+ Cell Quantitation: An Australian Multicenter StudyJournal of Hematotherapy, 1996
- Differences in the distribution of CD34 epitopes on normal haemopoietic progenitor cells and leukaemic blast cellsBritish Journal of Haematology, 1996
- Improved Priming for Mobilization of and Optimal Timing for Harvest of Peripheral Blood Stem CellsJournal of Hematotherapy, 1996
- The ISHAGE Guidelines for CD34+ Cell Determination by Flow CytometryJournal of Hematotherapy, 1996
- North American Multicenter Study on Flow Cytometric Enumeration of CD34+ Hematopoietic Stem CellsJournal of Hematotherapy, 1996
- Characterization and Measurement of CD34-Expressing Hematopoietic CellsJournal of Hematotherapy, 1994
- Commentary: Prospects for Standardization of Stem Cell Determination within EuropeJournal of Hematotherapy, 1993
- Report on the European Workshop on Peripheral Blood Stem Cell Determination and Standardization—Mulhouse, France, February 6-8 and 14-15, 1992Journal of Hematotherapy, 1992