Which Factors Increase Risk of Malalignment of the Hip-Knee-Ankle Axis in TKA?
Authors:
- Arun B. MullajiAMArun B. Mullaji
- Gautam M. ShettyGSGautam M. Shetty
- A. P. LingarajuALA. P. Lingaraju
- Sagar BhaydeSBSagar Bhayde
- 1 January 2013
- journal article
- research article
- Published by Wolters Kluwer Health in Clinical Orthopaedics and Related Research
- Vol. 471 (1) , 134-141
Abstract
(1) What is the incidence and characteristics of outliers for postoperative limb mechanical axis (hip-knee-ankle [HKA] angle outside the conventional 180° ± 3° range) and component alignment in TKA? And (2) what are the preoperative clinical or radiographic risk factors for limb mechanical axis malalignment in TKA? Methods We retrospectively reviewed the clinical and radiographic records of 1500 computer-assisted TKAs to identify outliers for postoperative HKA axis and component alignment and determined risk factors for malalignment. Full-length hip-to-ankle and knee radiographs were used to measure preoperative HKA angle, femoral coronal bowing, joint divergence angle, tibial subluxation, and tibial bone loss and postoperative HKA angle and femoral and tibial component angle. Results The incidence of outliers for postoperative limb mechanical axis, femoral component alignment, and tibial component alignment was 7% (112 of 1500 TKAs), 7%, and 8%, respectively, with 70% of limbs placed in excessive varus and 30% in excessive valgus. Preoperative varus deformity of more than 20° and femoral bowing of more than 5° were associated with increased risk of placing the limb mechanical axis outside the acceptable ± 3° range after computer-assisted TKA. Conclusions The presence of preoperative radiographic risk factors should alert the surgeon to increased chance of malalignment and every measure should be undertaken in such at-risk knees to ensure proper limb and component alignment and soft tissue balance. Level of Evidence Level II, prognostic study. See Instructions for Authors for a complete description of levels of evidence...Keywords
This publication has 28 references indexed in Scilit:
- Neutral Mechanical Alignment: A Requirement for Successful TKA: AffirmsOrthopedics, 2011
- Navigation of total knee arthroplasty: rotation of components and clinical results in a prospectively randomized studyBMC Musculoskeletal Disorders, 2011
- Coronal Alignment in Total Knee ArthroplastyThe Journal of Arthroplasty, 2009
- Good Alignment After Total Knee Arthroplasty Leads to Faster Rehabilitation and Better FunctionThe Journal of Arthroplasty, 2009
- Computer Navigation Did Not Improve Alignment in a Lower-volume Total Knee PracticeClinical Orthopaedics and Related Research, 2008
- Comparison of Limb and Component Alignment Using Computer-Assisted Navigation Versus Image Intensifier–Guided Conventional Total Knee ArthroplastyThe Journal of Arthroplasty, 2007
- Imageless Navigation for TKA Increases Implantation AccuracyClinical Orthopaedics and Related Research, 2007
- Soft Tissue Balance in Total Knee ArthroplastyClinical Orthopaedics and Related Research, 2006
- Computer Assisted Navigation in Total Knee ArthroplastyThe Journal of Arthroplasty, 2005
- Autologous bone grafting for medial tibial defects in total knee arthroplastyThe Journal of Arthroplasty, 1991