A biomechanical comparison of self-selected and experimentally controlled speeds and grip widths during the bench press exercise
Authors:
- 22 June 2020
- journal article
- research article
- Published by Taylor & Francis in Sports Biomechanics
- Vol. 22 (8) , 953-965
Abstract
The purpose of this study was to compare one repetition maximum (1RM), a rating of discomfort, and myoelectric activity between self-selected and experimentally controlled speeds and grip widths during the bench press (BP). Four BP conditions used were self-selected speed and grip (SS), self-selected speed and experimentally controlled grip (SC), experimentally controlled speed and self-selected grip (CS), and experimentally controlled speed and grip (CC). Twenty male individuals completed 1RM measurements with each BP condition and then performed 16 BP trials (four trials per condition) for measuring myoelectric activity. A one-way repeated measures analysis of variance was conducted for 1RM. Frequency analyses were conducted for a rating of discomfort. Two-way repeated measures multivariate analyses of variance were performed for myoelectric activity. SS showed a significantly higher 1RM than SC, CS, and CC. CC was characterised as the most uncomfortable BP condition (80%) followed by CS (15%), SC (5%), and SS (0%). There were no significant main effects and interaction of speed and width on myoelectric activity. A self-selected speed and grip width was recommended because it would allow a more practical and ecologically valid assessment of 1RM and a lower rating of discomfort during the BP.Keywords
Funding Information
- Western Michigan University (College of Education and Human Development International Collaborative Research Grant)
This publication has 19 references indexed in Scilit:
- An electromyographic and kinetic comparison of conventional and Romanian deadliftsJournal of Exercise Science & Fitness, 2018
- An Investigation of the Mechanics and Sticking Region of a One-Repetition Maximum Close-Grip Bench Press versus the Traditional Bench PressSports, 2017
- The effects of grip width on sticking region in bench pressJournal of Sports Sciences, 2015
- Maximal intended velocity training induces greater gains in bench press performance than deliberately slower half‐velocity trainingEuropean Journal of Sport Science, 2014
- Effect of Different Pushing Speeds on Bench PressInternational Journal of Sports Medicine, 2012
- How should we normalize electromyograms obtained from healthy participants? What we have learned from over 25years of researchJournal of Electromyography and Kinesiology, 2010
- Comparison of Lower Extremity Emg Between the 2-Leg Squat and Modified Single-Leg Squat in Female AthletesJournal of Sport Rehabilitation, 2010
- The Affect of Grip Width on Bench Press Performance and Risk of InjuryStrength & Conditioning Journal, 2007
- The Influence of Grip Width and Forearm Pronation/Supination on Upper-Body Myoelectric Activity During the Flat Bench PressJournal of Strength & Conditioning Research, 2005
- Effects of Variations of the Bench Press Exercise on the EMG Activity of Five Shoulder MusclesJournal of Strength & Conditioning Research, 1995