Utility of a new transcutaneous jaundice device with two optical paths in premature infants
Authors:
- 6 June 2007
- journal article
- Published by Wiley in Pediatrics International
- Vol. 49 (4) , 497-501
Abstract
Background: Hyperbilirubinemia may cause dysfunction of the central nervous system of newborn infants. Recently, a new transcutaneous bilirubin device has been developed, which is not limited by maturity or melanin concentration of the skin. However, there have been few reports limiting the subjects to preterm and very low-birthweight (VLBW) infants. Methods: Transcutaneous bilirubin (TcB) and total serum bilirubin (TSB) were measured within 1 h of time lag in 50 premature infants. TcB was measured with the new jaundice device on the forehead. TSB samples were measured by direct colorimetry. The correlation coefficient and regression line were calculated. Results: The results showed a good correlation between TcB and TSB. However, the correlation tended to be worse with infants whose birthweights were lower than 1000 g, or whose gestational ages at birth were shorter than 28 weeks. Conclusion: TcB and TSB have a close correlation, and TcB tends to be higher than TSB. The Minolta transcutaneous jaundice device could be used as a screening instrument, leading to the avoidance of invasive blood samplings for preterm and VLBW infants. However, in patients whose birthweights are lower than 1000 g or whose gestational ages are shorter than 28 weeks, care must be taken when using the transcutaneous jaundice device because of low reliability in these patients.Keywords
This publication has 15 references indexed in Scilit:
- Transcutaneous bilirubinometry in very low birthweight infantsActa Paediatrica, 2004
- Transcutaneous bilirubinometry in very low birthweight infantsActa Paediatrica, 2004
- Evaluation of a New Transcutaneous BilirubinometerPediatrics, 2004
- New transcutaneous jaundice device with two optical pathsJournal of Perinatal Medicine, 2003
- Avoiding painful blood sampling in neonates by transcutaneous bilirubinometryIrish Journal of Medical Science (1971 -), 2002
- A comparison of transcutaneous bilirubinometers: SpectRx BiliCheck versus Minolta AirShieldsArchives of Disease in Childhood - Fetal and Neonatal Edition, 2002
- Can transcutaneous bilirubinometry reduce the need for blood tests in jaundiced full term babies?Archives of Disease in Childhood - Fetal and Neonatal Edition, 2002
- Non-invasive bilirubinometry in neonatal jaundiceSeminars in Neonatology, 2002
- Transcutaneous bilirubinometry in preterm infantsActa Paediatrica, 2001
- Bilirubinbestimmungen mit einer direkten photometrischen Methode im Kapillarplasma (DPM, Bilirubinometer) und mit einer chemischen Bilirubinbestimmung (DPD-Methode) im Serum von venösen BlutprobenKlinische Padiatrie, 1988