Feasibility and safety of pulmonary vein isolation by high-power short-duration radiofrequency application: short-term results of the POWER-FAST PILOT study
- 12 November 2019
- journal article
- research article
- Published by Springer Nature in Journal of Interventional Cardiac Electrophysiology
- Vol. 57 (1) , 57-65
Abstract
Purpose Pulmonary vein (PV) isolation (PVI) by point-by-point radiofrequency application (PPRF) results in longer procedures than that achieved by single-shot ablation techniques. In addition, it is associated with significant risk of oesophageal injury. The POWER-FAST pilot study evaluated the feasibility and safety of PVI by high-power short-duration (HPSD) PPRF. Methods HPSD PPRF around the PVs was done in 48 consecutive patients with atrial fibrillation. Fifty watts was delivered until a predefined lesion index value was reached (LSI ≥ 5 or Abl-I ≥ 350) and 60 W during 7–10 s in the first 18 and last 30 patients, respectively. A control group of 47 consecutive patients who had undergone PVI before the HPSD group with conventional PPRF (30 W for 30 s) was included for reference. Echocardiography and oesophageal endoscopy was performed shortly after ablation in all patients. Results PVI of all targeted veins was achieved in 98% and 100% of patients of the conventional and HPSD groups, respectively (p = 0.59). Total radiofrequency time was 34 ± 11, 24 ± 8, and 15 ± 5 min in groups 30 W, 50 W, and 60 W (p < 0.001). Audible steam pops occurred in 4 out of 48 (8%) patients in the HPSD group, accounting for 4 (0.08%) out of 5 269 HPSD radiofrequency applications. No patient in the HPSD group developed pericardial effusion. The incidence of oesophageal lesions was 28%, 22%, and 0% in groups 30 W, 50 W, and 60 W, respectively (p = 0.007) Conclusions PVI can be achieved with HPSD PPRF in most patients. This approach appears safe and associated with low risk of esophageal damage.Keywords
Funding Information
- Sociedad Española de Cardiología (Clinical Research Project Dr. Pedro Zarzo 2014, SEC-BAYER Clinica Project 2018)
- Instituto de Salud Carlos III (Clinical Research Project PI18/01522, 2018)
This publication has 17 references indexed in Scilit:
- High-Power and Short-Duration Ablation for Pulmonary Vein IsolationJACC: Clinical Electrophysiology, 2018
- Evaluation of a Strategy Aiming to Enclose the Pulmonary Veins With Contiguous and Optimized Radiofrequency Lesions in Paroxysmal Atrial FibrillationJACC: Clinical Electrophysiology, 2018
- 2017 HRS/EHRA/ECAS/APHRS/SOLAECE expert consensus statement on catheter and surgical ablation of atrial fibrillationEP Europace, 2017
- In Vitro Validation of the Lesion Size Index to Predict Lesion Width and Depth After Irrigated Radiofrequency Ablation in a Porcine ModelJACC: Clinical Electrophysiology, 2017
- Risk of atrioesophageal fistula formation with contact force–sensing cathetersHeart Rhythm, 2017
- Progression From Esophageal Thermal Asymptomatic Lesion to Perforation Complicating Atrial Fibrillation AblationCirculation: Arrhythmia and Electrophysiology, 2017
- Dabigatran‐induced esophagitis: The prevalence and endoscopic characteristicsJournal of Gastroenterology and Hepatology, 2015
- Incidental and ablation-induced findings during upper gastrointestinal endoscopy in patients after ablation of atrial fibrillation: A retrospective study of 425 patientsHeart Rhythm, 2014
- Atrial Fibrillation Ablation: “Perpetual Motion” of Open Irrigated Tip Catheters at 50 W Is Safe and Improves OutcomesPacing and Clinical Electrophysiology, 2011