Inductively Coupled Plasma Optical Emission Spectrometry
Authors:
- Xiandeng HouXHXiandeng Hou
- Renata S. AmaisRARenata S. Amais
- Bradley T. JonesBJBradley T. Jones
- George L. DonatiGDGeorge L. Donati
- 9 March 2016
- book chapter
- Published by Wiley
- p. 1-25
Abstract
Inductively coupled plasma optical emission spectrometry (ICP OES) is a powerful tool for the determination of many elements in a variety of different sample matrices. With this method, liquid samples are injected into a radiofrequency (RF)‐induced argon plasma using one of a variety of nebulizers or sample introduction techniques. The sample mist reaching the plasma is quickly dried, vaporized, and energized through collisional excitation at high temperature. The atomic emission emanating from the plasma is viewed in either a radial or axial configuration, collected with a lens or mirror, and imaged onto the entrance slit of a wavelength selection device. Single‐element measurements can be performed cost‐effectively with a simple monochromator–photomultiplier tube (PMT) combination, and simultaneous multielement determinations are performed for up to 70 elements with the combination of a polychromator and an array detector. The analytical performance of such systems is competitive with most other inorganic analysis techniques, especially with regard to sample throughput and sensitivity.Keywords
This publication has 60 references indexed in Scilit:
- An Overview of the Use of Yttrium for Internal Standardization in Inductively Coupled Plasma–Atomic Emission SpectrometryApplied Spectroscopy Reviews, 2010
- Speciation of gadolinium in gadolinium-based magnetic resonance imaging agents by high performance liquid chromatography inductively coupled plasma optical emission spectrometryJournal of Analytical Atomic Spectrometry, 2009
- Slurry Nebulization in Plasmas for Analysis of Inorganic MaterialsApplied Spectroscopy Reviews, 2006
- Comparison of pneumatic and ultrasonic nebulizations in inductively coupled plasma atomic emission spectrometry — matrix effects and plasma parametersSpectrochimica Acta Part B: Atomic Spectroscopy, 2006
- Direct Determination of Cadmium in Urine by Electrothermal Vaporizer—Inductively Coupled Plasma Analysis Using a Tungsten Coil VaporizerApplied Spectroscopy, 2005
- Elemental analysis of liquid microsamples through inductively coupled plasma spectrochemistryTrAC Trends in Analytical Chemistry, 2005
- External Standards or Standard Addition? Selecting and Validating a Method of StandardizationJournal of Chemical Education, 2002
- Imaging applications for chemical analysis utilizing charge coupled device array detectorsTrAC Trends in Analytical Chemistry, 1993
- Chromatography coupled with inductively coupled plasma atomic emission spectrometry and inductively coupled plasma mass spectrometry. A reviewJournal of Analytical Atomic Spectrometry, 1993
- Electrothermal Vaporization for Sample Introduction in Plasma Source SpectrometryCritical Reviews in Analytical Chemistry, 1992