Optimal Design of Point-Focusing Shear Vertical Wave Electromagnetic Ultrasonic Transducers Based on Orthogonal Test Method
Authors:
- 13 August 2018
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 18 (19) , 8064-8073
Abstract
The lower conversion efficiency is the main drawback of electromagnetic acoustic transducers (EMATs) compared with other transducers, which limits their use in many industrial applications. In this paper, for enhancing the performance of point-focusing shear vertical wave EMATs (PFSV-EMATs), 18 orthogonal tests with seven factors and three levels are conducted through finite-element simulations. First, the degree of seven factors on the signal amplitude, axial focus offset, and radial focus offset is obtained by range analysis and compared. It indicates that the effect of the liftoff distance and the exciting current on signal amplitude is the largest, while the effect of the inner radius of concentric meander-line coils on the axial and radial focal offset is the largest. Then, the influence degree of various factors on test results is analyzed at frequencies of 1.5, 2, and 2.5 MHz, showing that the relatively low frequency, i.e., the sparser coil spacing, is favorable for signal amplitude and detrimental for point-focusing ability. Finally, experiments are carried out to verify the validation of optimization results, which indicates that the increased signal amplitude of 88.78%, smaller axial focus offset, and zero radial focus offset can be achieved by the optimized PFSV-EMAT, which has the improved signal amplitude and point-focusing behavior, compared with the non-optimized one.Keywords
Funding Information
- National Natural Science Foundation of China (51374264)
- Entrepreneurship and Innovation Foundation for Returned Overseas Scholars, Chongqing City of China (CX2017004)
This publication has 28 references indexed in Scilit:
- Numerical and experimental analysis of unidirectional meander-line coil electromagnetic acoustic transducersIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 2013
- Optimal Design of Lamb Wave Electromagnetic Acoustic Transducers for Improving Their Excitation PerformanceJapanese Journal of Applied Physics, 2011
- Coupling mechanism of an EMATUltrasonics, 2006
- Orthogonal test design for optimization of supercritical fluid extraction of daphnoretin, 7-methoxy-daphnoretin and 1,5-diphenyl-1-pentanone from Stellera chamaejasme L. and subsequent isolation by high-speed counter-current chromatographyJournal of Chromatography A, 2006
- A model for pulsed Rayleigh wave and optimal EMAT designSensors and Actuators A: Physical, 2006
- Optimal design of EMAT transmittersNDT & E International, 2004
- Industrially viable non-contact ultrasoundInsight - Non-Destructive Testing and Condition Monitoring, 2003
- Field dependence of coupling efficiency between electromagnetic field and ultrasonic bulk wavesJournal of Applied Physics, 1997
- A two-dimensional Fourier transform method for the measurement of propagating multimode signalsThe Journal of the Acoustical Society of America, 1991
- Theory and numerical calculation of the acoustic field produced in metal by an electromagnetic ultrasonic transducerThe Journal of the Acoustical Society of America, 1976