Translation of Carbon‐13 EPI for hyperpolarized MR molecular imaging of prostate and brain cancer patients
- 30 October 2018
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 81 (4) , 2702-2709
Abstract
Purpose: To develop and translate a metabolite‐specific imaging sequence using a symmetric echo planar readout for clinical hyperpolarized (HP) Carbon‐13 (13C) applications.Methods: Initial data were acquired from patients with prostate cancer (N = 3) and high‐grade brain tumors (N = 3) on a 3T scanner. Samples of [1‐13C]pyruvate were polarized for at least 2 h using a 5T SPINlab system operating at 0.8 K. Following injection of the HP substrate, pyruvate, lactate, and bicarbonate (for brain studies) were sequentially excited with a singleband spectral‐spatial RF pulse and signal was rapidly encoded with a single‐shot echo planar readout on a slice‐by‐slice basis. Data were acquired dynamically with a temporal resolution of 2 s for prostate studies and 3 s for brain studies.Results: High pyruvate signal was seen throughout the prostate and brain, with conversion to lactate being shown across studies, whereas bicarbonate production was also detected in the brain. No Nyquist ghost artifacts or obvious geometric distortion from the echo planar readout were observed. The average error in center frequency was 1.2 ± 17.0 and 4.5 ± 1.4 Hz for prostate and brain studies, respectively, below the threshold for spatial shift because of bulk off‐resonance.Conclusion: This study demonstrated the feasibility of symmetric EPI to acquire HP 13C metabolite maps in a clinical setting. As an advance over prior single‐slice dynamic or single time point volumetric spectroscopic imaging approaches, this metabolite‐specific EPI acquisition provided robust whole‐organ coverage for brain and prostate studies while retaining high SNR, spatial resolution, and dynamic temporal resolution.Keywords
Funding Information
- National Institutes of Health (R01EB017449, R01CA183071, P41EB013598, P01CA118816, and R01CA211150)
This publication has 29 references indexed in Scilit:
- Improved tolerance to off‐resonance in spectral‐spatial EPI of hyperpolarized [1‐13C]pyruvate and metabolitesMagnetic Resonance in Medicine, 2018
- Development of methods and feasibility of using hyperpolarized carbon‐13 imaging data for evaluating brain metabolism in patient studiesMagnetic Resonance in Medicine, 2018
- Hyperpolarized 1-[ 13 C]-Pyruvate Magnetic Resonance Imaging Detects an Early Metabolic Response to Androgen Ablation Therapy in Prostate CancerEuropean Urology, 2017
- Dual‐Echo EPI sequence for integrated distortion correction in 3D time‐resolved hyperpolarized 13C MRIMagnetic Resonance in Medicine, 2017
- An indirect method for in vivo T2 mapping of [1‐13C] pyruvate using hyperpolarized 13C CSINMR in Biomedicine, 2017
- Optimizing Flip Angles for Metabolic Rate Estimation in Hyperpolarized Carbon-13 MRIIEEE Transactions on Medical Imaging, 2016
- A novel perfused Bloch–McConnell simulator for analyzing the accuracy of dynamic hyperpolarized MRSMedical Physics, 2016
- Rapid multislice imaging of hyperpolarized 13C pyruvate and bicarbonate in the heartMagnetic Resonance in Medicine, 2010
- Pulse sequence for dynamic volumetric imaging of hyperpolarized metabolic productsJournal of Magnetic Resonance, 2008
- Increase in signal-to-noise ratio of > 10,000 times in liquid-state NMRProceedings of the National Academy of Sciences of the United States of America, 2003