Comparison of the Diagnostic Accuracy of Semiautomated and Expert-Based Calculation of the Vertebral Heart Score in Cats and Dogs: First Stage Validation of the “Desktop Application for Automation of the VHS Calculation Based on Radiographs”
Open Access
- 8 July 2026
- journal article
- Published by FSFEI HE Don State Technical University in Russian Journal of Veterinary Pathology
- Vol. 25 (2) , 44-53
Abstract
Introduction . Cardiac diseases are considered to be among the main causes of mortality in small domestic animals. Calculation of the vertebral heart score (VHS) is a method used to assess the cardiac silhouette enlargement on radiographs and predict the development of congestive heart failure. However, traditional manual procedure of VHS calculation is characterized by high inter-observer variability, subjectivity, and significant time-consumption. To improve the access to objective cardiac screening in every-day clinical practice, the authors has developed a desktop application for automating VHS calculation using the artificial intelligence (AI) technologies that unifies the assessment standard, minimizes human error, and accelerates processing of radiographs. The aim of the present pilot research is to conduct the first stage validation of the application and compare the diagnostic accuracy of two VHS calculation methods — semiautomated and expert-based. Materials and Methods. A balanced sample of 30 right lateral chest radiographs of dogs and cats was selected for analysis as a result of simple random sampling. Preliminary VHS was calculated by manual measurements on the radiographs by the Buchanan & Bücheler method: two veterinarians specializing in visual diagnostics measured the short and long axes of the heart on the radiographs and then compared their dimensions against the spinal vertebrae. The semi-automated calculation of VHS was performed by the author-developed “Desktop application for automation of the vertebral heart score (VHS) calculation based on radiographs” using a convolutional neural network. App validation implied a comparison of the results of the two methods of VHS calculation, taking into account the intraclass correlation coefficient (ICC). Results . The “Desktop application for automation of the vertebral heart score (VHS) calculation based on radiographs” has proved to perform a highly accurate and replicable automated calculation of VHS on lateral chest radiographs of dogs and cats. It also has demonstrated statistically high agreement with the calculations obtained by veterinarians specializing in visual diagnostics (ICC≥0.97), along with less time required for calculation. Discussion and Conclusion. The first stage of app validation has demonstrated an excellent agreement between the AI and two specialists’ results, therefore, the proposed approach can be deemed a future-oriented tool for general practitioners. The present pilot research has several limitations, i.e. it was conducted on a relatively small sample of animals, which may be insufficient for evaluation of app performance in narrow subgroups (e.g., in specific breeds or in severe cardiomegaly cases). Further studies in larger, more heterogeneous cohorts, including patients with severe cardiomegaly and anatomical abnormalities, are required to confirm clinical significance of the results.Keywords
This publication has 14 references indexed in Scilit:
- Artificial intelligence in veterinary diagnostic imaging: A literature reviewVeterinary Radiology & Ultrasound, 2022
- Artificial intelligence evaluating primary thoracic lesions has an overall lower error rate compared to veterinarians or veterinarians in conjunction with the artificial intelligenceVeterinary Radiology & Ultrasound, 2020
- Guidelines for clinical trial protocols for interventions involving artificial intelligence: the SPIRIT-AI ExtensionBMJ, 2020
- Utility of radiographic measurements to predict echocardiographic left heart enlargement in dogs with preclinical myxomatous mitral valve diseaseJournal of Veterinary Internal Medicine, 2020
- ACVIM consensus guidelines for the diagnosis and treatment of myxomatous mitral valve disease in dogsJournal of Veterinary Internal Medicine, 2019
- Automatic Cardiothoracic Ratio Calculation With Deep LearningIEEE Access, 2019
- Erratum to “A Guideline of Selecting and Reporting Intraclass Correlation Coefficients for Reliability Research” [J Chiropr Med 2016;15(2):155-163]Journal of Chiropractic Medicine, 2017
- Deep Convolutional Network Cascade for Facial Point Detection2013
- Rate of change of heart size before congestive heart failure in dogs with mitral regurgitationJournal of Small Animal Practice, 2010
- INTEROBSERVER VARIABILITY OF VERTEBRAL HEART SIZE MEASUREMENTS IN DOGS WITH NORMAL AND ENLARGED HEARTSVeterinary Radiology & Ultrasound, 2005