Experimental verification of a piezoelectric smart isolation system
Authors:
- 5 July 2010
- journal article
- research article
- Published by Hindawi Limited in Structural Control and Health Monitoring
- Vol. 18 (8) , 869-889
Abstract
To improve the performance of conventional seismic isolation technology, a semi‐active isolation system, named a ‘Piezoelectric Smart Isolation System (PSIS)’, which is composed of a sliding isolation platform and a piezoelectric friction damper (PFD), is introduced and investigated experimentally in this study. Because the friction force of the PFD in the PSIS can be regulated by an embedded piezoelectric actuator through a DC voltage, the PFD is able to provide a controllable damping force for the isolation system. As a result, the seismic response of the PSIS can be effectively controlled and mitigated. In order to verify its feasibility, a prototype PSIS was fabricated and tested dynamically via a shaking table test. The accuracy of the test data has been confirmed by the good consistency between the experimental and theoretical results. The experimental results have demonstrated that, when compared to the uncontrolled counterpart, the PSIS is able to substantially suppress both the displacement and acceleration responses in an earthquake with either near‐fault or far‐field characteristics. The study has also shown that, although the semi‐active PSIS system can only provide a variable passive control force, it is able to achieve the same level of control performance as an actively controlled isolation system, which shares the same optimal feedback gain as that of the PSIS. Copyright © 2010 John Wiley & Sons, Ltd.Keywords
This publication has 36 references indexed in Scilit:
- Analytical Model of Ground Motion Pulses for the Design and Assessment of Seismic Protective SystemsJournal of Structural Engineering, 2008
- Explicit Directivity‐Pulse Inclusion in Probabilistic Seismic Hazard AnalysisEarthquake Spectra, 2007
- Quantitative Classification of Near-Fault Ground Motions Using Wavelet AnalysisBulletin of the Seismological Society of America, 2007
- Influence of isolator characteristics on the response of base-isolated structuresEngineering Structures, 2004
- A parametric study of linear and non-linear passively damped seismic isolation systems for buildingsEngineering Structures, 2004
- Experimental and analytical studies on the performance of hybrid isolation systemsEarthquake Engineering & Structural Dynamics, 2001
- Base isolation for near‐fault motionsEarthquake Engineering & Structural Dynamics, 2001
- Effect of viscous, viscoplastic and friction damping on the response of seismic isolated structuresEarthquake Engineering & Structural Dynamics, 2000
- Design of Seismic Isolated Structures1999