Impact of real-time contact force and impedance measurement in pulmonary vein isolation procedures for treatment of atrial fibrillation
- 6 October 2013
- journal article
- research article
- Published by Springer Nature in Clinical Research in Cardiology
- Vol. 103 (2) , 97-106
Abstract
Background Pulmonary vein isolation (PVI) is an established procedure to treat atrial fibrillation (AF). New techniques are necessary to improve procedural parameters like shortening of procedure duration. Real-time contact force (CF) catheters are new tools aiming to improve PVI by optimizing electrode–tissue contact and generating more effective lesions. Objective of this study was to investigate the influence on procedural parameters and clinical outcome by using a CF catheter for PVI. Methods PVI was performed on 67 consecutive patients using a CF catheter (n = 32) or a standard ablation catheter (SAC, n = 35). Study endpoints included number of energy applications, impedance drop, fluoroscopy time, and left atrial (LA) procedure time and freedom from AF after 6 and 12 months. Results Procedural endpoint was reached in all patients with a similar clinical outcome (freedom from AF) in both groups 6 months (62.9 vs. 62.5 %) and 12 months post PVI (59.4 vs. 62.9 % in CF vs. SAC group, respectively). However, CF-guided ablation resulted in a greater fall of impedance (6.58 ± 0.33 vs. 9.09 ± 0.53 Ω, *** p < 0.001), lower number of energy applications (44.20 ± 3.67 vs. 34.06 ± 3.11, * p < 0.05), reduction of LA procedure time (95.52 ± 7.35 vs. 78.08 ± 7.23* min) and a significant reduction of fluoroscopy time (51.4 ± 3.3 vs. 33.0 ± 2.7*** min). In addition, a detailed analysis showed a significant correlation between quantitative impedance drop and amount of CF applied, suggesting more efficient lesion creation by CF-guided ablation. Conclusion Use of CF catheters in PVI has a beneficial effect on procedural parameters, probably by improving efficacy of transmural lesion formation.Keywords
This publication has 34 references indexed in Scilit:
- Types and outcomes of cardioversion in patients admitted to hospital for atrial fibrillation: results of the German RHYTHM-AF StudyClinical Research in Cardiology, 2013
- Atrial fibrillation, elevated troponin, ischemic stroke and adverse outcomes: understanding the connectionClinical Research in Cardiology, 2013
- Renal artery ablation instead of pulmonary vein ablation in a hypertensive patient with symptomatic, drug-resistant, persistent atrial fibrillationClinical Research in Cardiology, 2012
- Contact force–controlled zero-fluoroscopy catheter ablation of right-sided and left atrial arrhythmia substratesHeart Rhythm, 2012
- Remote magnetic versus manual catheter navigation for circumferential pulmonary vein ablation in patients with atrial fibrillationClinical Research in Cardiology, 2011
- Management of atrial fibrillation by primary care physicians in Germany: baseline results of the ATRIUM registryClinical Research in Cardiology, 2011
- Sternal fracture after elective electrical cardioversion of atrial fibrillationClinical Research in Cardiology, 2010
- Importance of Catheter Contact Force During Irrigated Radiofrequency Ablation: Evaluation in a Porcine Ex Vivo Model Using a Force‐Sensing CatheterJournal of Cardiovascular Electrophysiology, 2010
- Novel Contact Force Sensor Incorporated in Irrigated Radiofrequency Ablation Catheter Predicts Lesion Size and Incidence of Steam Pop and ThrombusCirculation: Arrhythmia and Electrophysiology, 2008
- Effects of dispersive electrode position and surface area on electrical parameters and temperature during radiofrequency catheter ablationThe American Journal of Cardiology, 1996