Internal energy distributions in desorption electrospray ionization (DESI)
- 1 March 2008
- journal article
- Published by American Chemical Society (ACS) in Journal of the American Society for Mass Spectrometry
- Vol. 19 (3) , 420-427
Abstract
The internal energy distributions of typical ions generated by desorption electrospray ionization (DESI) were measured using the "survival yield" method, and compared with corresponding data for electrospray ionization (ESI) and electrosonic spray ionization (ESSI). The results show that the three ionization methods produce populations of ions having internal energy distributions of similar shapes and mean values (1.7-1.9 eV) suggesting similar phenomena, at least in the later stages of the process leading from solvated droplets to gas-phase ions. These data on energetics are consistent with the view that DESI involves "droplet pick-up" (liquid-liquid extraction) followed by ESI-like desolvation and gas-phase ion formation. The effects of various experimental parameters on the degree of fragmentation of p-methoxy-benzylpyridinium ions were compared between DESI and ESSI. The results show similar trends in the survival yields as a function of the nebulizing gas pressure, solvent flow rate, and distance from the sprayer tip to the MS inlet. These observations are consistent with the mechanism noted above and they also enable the user to exercise control over the energetics of the DESI ionization process, through manipulation of external and internal ion source parameters.Keywords
This publication has 61 references indexed in Scilit:
- Forensic analysis of inks by imaging desorption electrospray ionization (DESI) mass spectrometryThe Analyst, 2007
- Desorption electrospray ionisation mass spectrometric analysis of chemical warfare agents from solid‐phase microextraction fibersRapid Communications in Mass Spectrometry, 2007
- Tissue Imaging at Atmospheric Pressure Using Desorption Electrospray Ionization (DESI) Mass SpectrometryAngewandte Chemie International Edition, 2006
- Automated Sampling and Imaging of Analytes Separated on Thin-Layer Chromatography Plates Using Desorption Electrospray Ionization Mass SpectrometryAnalytical Chemistry, 2006
- Non-proximate detection of explosives and chemical warfare agent simulants by desorption electrospray ionization mass spectrometryChemical Communications, 2006
- Desorption electrospray ionization with a portable mass spectrometer: in situ analysis of ambient surfacesChemical Communications, 2006
- Liquid chromatography electrospray tandem mass spectrometric and desorption electrospray ionization tandem mass spectrometric analysis of chemical warfare agents in office media typically collected during a forensic investigationJournal of Chromatography A, 2006
- Rapid analysis of controlled substances using desorption electrospray ionization mass spectrometryRapid Communications in Mass Spectrometry, 2005
- Mass Spectrometric Profiling of Intact Biological Tissue by Using Desorption Electrospray IonizationAngewandte Chemie International Edition, 2005
- Mass Spectrometry Sampling Under Ambient Conditions with Desorption Electrospray IonizationScience, 2004