Abstract
Capacitive deionization (CDI) is an emerging technology selective removal of ions from water. While many studies have reported chemically tailored electrodes for selective ion removal, the selective removal of divalent cations (i.e. hardness) over monovalent cations can simply be achieved using membrane CDI (MCDI) equipped with ion exchange membranes (IEMs). In this study, we use both experimental and modeling approaches to systematically investigate the selective removal of Ca2+ over Na+. Specifically, the impacts of current density, hydraulic retention time, and feed composition on the selectivity of Ca2+ over Na+ were investigated. The results from our study suggest a universal correlation between the ratio of molar fluxes and the ratio of spacer channel ion concentrations, regardless of operating conditions and feed composition. Our analysis also reveals inherent and universal tradeoff relationships between selectivity and the Ca2+ removal rate, and between selectivity and the degree of Ca2+ removal. These findings help us acquire fundamental understanding of the mechanism of selective ion removal in MCDI, which is also applicable to other flow electrode CDI processes that employs IEMs.
Funding Information
  • Division of Chemical, Bioengineering, Environmental and Transport Systems (1739884)