Otosclerosis
- 1 August 2012
- journal article
- otosclerosis
- Published by Wolters Kluwer Health in Otology & Neurotology
- Vol. 33 (6) , 922-927
Abstract
Objective To assess the use of cone beam computed tomography (CBCT) compared with multi-slice computed tomography (MSCT) in otosclerosis, with special emphasis on middle- and inner-ear anatomy. Study Design Prospective study. Patients Twenty patients who underwent a stapedectomy 30 years ago were selected on the basis of bone conduction threshold values. Their mean age was 65 years (range, 48–76 yr). Intervention All patients underwent CBCT and MSCT with a slice thickness of 0.5 to 0.6 mm. Main Outcome Measures Sixteen middle- and inner-ear anatomic structures and stapedial prostheses were analyzed by visual grading analysis. To assess critical reproduction and thereby the clinical applicability of CBCT, a dichotomization was made. Assessment of otosclerotic foci was performed using a grading system dividing the lesions in; 1) sole fenestral lesions, 2) retrofenestral lesions with or without fenestral lesions and 3) severe retrofenestral lesions. Results The 16 anatomic structures were clearly reproduced by both imaging techniques. However, there was an interobserver variation in judging the superiority of 1 method in favor of the other. Otosclerotic lesions were diagnosed in 80/95% using MSCT and 50/85% using CBCT (evaluators 1 and 2, respectively). Retrofenestral lesions were diagnosed in 5 of 10 of ears with severe-to-profound hearing loss, whereas no retrofenestral lesions were diagnosed in the 10 ears with mild-to-moderate hearing loss. The stapedial prostheses were adequately or very well reproduced by both methods. Conclusion CBCT is a new imaging technique with a considerably lower radiation dose than conventional MSCT. Our study indicates that CBCT is suitable and, in many ways, equivalent to MSCT, for temporal bone imaging in otosclerosis.Keywords
This publication has 20 references indexed in Scilit:
- A comparative study for spatial resolution and subjective image characteristics of a multi-slice CT and a cone-beam CT for dental useEuropean Journal of Radiology, 2011
- Imaging of Osseointegrated Implants in the Temporal Bone by Accuitomo 3-Dimensional Cone Beam Computed TomographyOtology & Neurotology, 2011
- A comparative evaluation of Cone Beam Computed Tomography (CBCT) and Multi-Slice CT (MSCT)European Journal of Radiology, 2010
- A method to analyse observer disagreement in visual grading studies: example of assessed image quality in paediatric cerebral multidetector CT imagesBritish Journal of Radiology, 2010
- Dosimetry and image quality of four dental cone beam computed tomography scanners compared with multislice computed tomography scannersDentomaxillofacial Radiology, 2009
- Conebeam CT of the Head and Neck, Part 1: Physical PrinciplesAmerican Journal of Neuroradiology, 2009
- Cone Beam Computed Tomography, A Low-Dose Imaging Technique in the Postoperative Assessment of Cochlear ImplantationOtology & Neurotology, 2009
- Calculating effective dose on a cone beam computed tomography device: 3D Accuitomo and 3D Accuitomo FPDDentomaxillofacial Radiology, 2008
- Sensorineural Hearing Loss and Otosclerosis: A Clinical and Radiologic Survey of 437 CasesActa Oto-Laryngologica, 2001
- Development of a compact computed tomographic apparatus for dental useDentomaxillofacial Radiology, 1999