Ultrashort laser based two-photon phase-resolved fluorescence lifetime measurement method
Authors:
- 19 February 2020
- journal article
- research article
- Published by IOP Publishing in Methods and Applications in Fluorescence
- Vol. 8 (2) , 025003
Abstract
This paper presents a two-photon phase-resolved fluorescence-lifetime measurement method based on the use of an ultrashort pulse laser. The proposed method also involves the use of a lock-in amplifier to control the phase difference between the reference and fluorescence signals, thereby facilitating the use of an alternative method for determining fluorescence lifetimes. Verification of the fluorescence lifetimes as measured in this study was performed using rhodamine B and a cellular thermoprobe as samples. In this study, we assume that the fluorescence decay was monoexponential in all cases. Rhodamine B was observed to exhibit an average fluorescence lifetime of 2.15 ns, whereas a temperature sensitivity of 1.39 ns C −1 over a temperature range of 33.79–37.2 °C was demonstrated for the cellular thermoprobe. These results validate the feasibility of the proposed method for accurate measurement of fluorescence lifetimes using a simple laser configuration.Keywords
Funding Information
- Adaptable and Seamless Technology transfer Program (A-STEP),JST
- JSPS Core-to-Core Program: A. Advanced Research Networks
This publication has 20 references indexed in Scilit:
- Exploration of the two‐photon excitation spectrum of fluorescent dyes at wavelengths below the range of the Ti:Sapphire laserJournal of Microscopy, 2015
- A Cell-Permeable Fluorescent Polymeric Thermometer for Intracellular Temperature Mapping in Mammalian Cell LinesPLOS ONE, 2015
- Testing Fluorescence Lifetime Standards using Two-Photon Excitation and Time-Domain Instrumentation: Rhodamine B, Coumarin 6 and Lucifer YellowJournal of Fluorescence, 2014
- Fluorescence Lifetime Imaging Microscopy for Quantitative Biological Imaging2013
- Fluorescence Lifetime Techniques in Medical ApplicationsAnnals of Biomedical Engineering, 2012
- Effects of incomplete decay in fluorescence lifetime estimationBiomedical Optics Express, 2011
- Saturable and reverse saturable absorption of Rhodamine B in methanol and waterJournal of the Optical Society of America B, 2003
- Fluorescence lifetime imaging for the two-photon microscope: time-domain and frequency-domain methodsJournal of Biomedical Optics, 2003
- Simultaneous measurement of the fluorescence spectrum and lifetime of Rhodamine B in solution with a fluorometer based on streak-camera technologiesAnalytical Chemistry, 1995
- Fluorescence decays and spectral properties of rhodamine B in submono-, mono-, and multilayer systemsThe Journal of Physical Chemistry, 1986