Causes of Phakic Implantable Collamer Lens Explantation/Exchange at King Khaled Eye Specialist Hospital
Open Access
- 1 October 2016
- journal article
- research article
- Published by Wolters Kluwer Health in Middle East African Journal of Ophthalmology
- Vol. 23 (4) , 293-295
Abstract
PURPOSE: The purpose of this study is to evaluate the causes of phakic implantable collamer lens (ICL) explantation/exchange at an eye hospital in Saudi Arabia. MATERIALS AND METHODS: A retrospective chart review was performed for patients who underwent ICL implantation from 2007 to March 2014 and data were collected on cases that underwent ICL explantation. RESULTS: Of the 787 ICL implants, 30 implants (3.8% [95% confidence interval 2.6%; 5.3%]) were explanted. The causes of explantation included incorrect lens size (22), cataract (4), high residual astigmatism (2), rhegmatogenous retinal detachment (1), and intolerable glare (1). Corrective measures mainly included an exchange with an appropriately sized lens (9), ICL explantation (11), with phacoemulsification and posterior chamber intraocular lens implantation (6), or replacement with an ICL of correct power (2). CONCLUSION: Incorrect ICL size was the most common cause of ICL explantation. More accurate sizing methods for ICL are required to reduce the explantation/exchange rate.Keywords
This publication has 9 references indexed in Scilit:
- Causes of elevated intraocular pressure following implantation of phakic intraocular lenses for myopiaInternational Ophthalmology, 2015
- Bilateral Explantation of Visian Implantable Collamer Lenses Secondary to Bilateral Acute Angle Closure Resulting from a Non-Pupillary Block MechanismJournal of Refractive Surgery, 2010
- Meridional differences in internal dimensions of the anterior segment in human eyes evaluated with 2 imaging systemsJournal of Cataract & Refractive Surgery, 2008
- Ultrasound Biomicroscopy for Determining Visian Implantable Contact Lens Length in Phakic IOL ImplantationJournal of Refractive Surgery, 2007
- Visian Collamer Phakic Intraocular Lens in High Myopic Asian EyesJournal of Refractive Surgery, 2007
- United States Food and Drug Administration clinical trial of the Implantable Collamer Lens (ICL) for moderate to high myopiaOphthalmology, 2004
- U.S. Food and Drug Administration clinical trial of the Implantable Contact Lens for moderate to high myopiaOphthalmology, 2003
- Predicting sulcus size using ocular measurementsJournal of Cataract & Refractive Surgery, 2001
- Posterior chamber collamer phakic intraocular lens for myopia and hyperopia.1999