Background and Objectives Major technical developments have been made in recent years to improve the quality and safety of human plasma for transfusion and fractionation. The present study was performed to assess, for the first time, the feasibility of applying a nanofiltration process, using 75‐nm and 35‐nm mean pore size membranes (Planova® 75N and Planova® 35N), to human plasma.Materials and Methods Ten apheresis plasma units were obtained from 10 plasma donors. Within 4 h of collection, plasma was subjected to leucoreduction and filtration (using 75‐nm and 35‐nm mean pore size membranes) at 35 °C, at less than 1 bar pressure. Aliquots of plasma were taken at all steps of the filtration procedure and numerous plasma quality parameters were measured. In addition, six hepatitis C virus (HCV)‐positive plasma donations were experimentally subjected to the same filtration sequence and subsequently assessed by RNA polymerase chain reaction (PCR) and branched‐chain DNA‐quantification assays.Results Leucoreduced plasma can be reproducibly nanofiltered onto a sequence of 75‐nm and 35‐nm membranes, at a flow rate of 450 ml/h and a temperature of 35 ± 0·5 °C. Some protein dilution, or loss, was found during filtration, but the plasma filtered through membranes with a mean pore size of 75 nm and 35 nm met in vitro specifications for use in transfusion or fractionation. There were no signs of activation of the coagulation system. HCV‐positive plasma donations became negative, as judged by PCR and branched‐chain DNA assay results, after filtration through the 35‐nm membrane.Conclusions It is possible to apply a 75 + 35‐nm filtration process to leucoreduced human plasma. This technology may have important future benefits in improving the quality and safety of plasma, by removing blood cell debris and infectious agents.Keywords
This publication has 40 references indexed in Scilit:
- Comparative Study on Collagen-Binding Enzyme-Linked Immunosorbent Assay and Ristocetin Cofactor Activity Assays for Detection of Functional Activity of von Willebrand FactorSeminars in Thrombosis and Hemostasis, 2002
- Scrapie Removal using Planova®Virus Removal FiltersBiologicals, 2001
- Immunological aspects of blood transfusionsBlood Reviews, 2000
- Studies on the Removal of Abnormal Prion Protein by Processes Used in the Manufacture of Human Plasma ProductsVox Sanguinis, 2000
- Preliminary assessment of whole-blood, red-cell and platelet- leucodepleting filters for possible induction of prion release by leucocyte fragmentation during room temperature processingBritish Journal of Haematology, 1999
- Removal of Viruses from Human Intravenous Immune Globulin by 35 nm NanofiltrationBiologicals, 1998
- The effect of methylene blue phototreatment on plasma proteins and in vitro coagulation capability of single‐donor fresh‐frozen plasmaTransfusion, 1994
- Contamination of fresh-frozen plasma with viable white cells and proliferable stem cellsTransfusion, 1994
- Viral Inactivation of Vesicular Stomatitis Virus in Normal Human Serum by Cross-Linked PolyvinylpyrrolidoneThe Journal of Infectious Diseases, 1993
- Fresh Frozen Plasma: Indications and RisksTransfusion Medicine Reviews, 1987