DuDoSS: Deep‐learning‐based dual‐domain sinogram synthesis from sparsely sampled projections of cardiac SPECT
Authors:
- 28 September 2022
- journal article
- research article
- Published by Wiley in Medical Physics
- Vol. 50 (1) , 89-103
Abstract
Purpose: Myocardial perfusion imaging (MPI) using single‐photon emission‐computed tomography (SPECT) is widely applied for the diagnosis of cardiovascular diseases. In clinical practice, the long scanning procedures and acquisition time might induce patient anxiety and discomfort, motion artifacts, and misalignments between SPECT and computed tomography (CT). Reducing the number of projection angles provides a solution that results in a shorter scanning time. However, fewer projection angles might cause lower reconstruction accuracy, higher noise level, and reconstruction artifacts due to reduced angular sampling. We developed a deep‐learning‐based approach for high‐quality SPECT image reconstruction using sparsely sampled projections.Methods: We proposed a novel deep‐learning‐based dual‐domain sinogram synthesis (DuDoSS) method to recover full‐view projections from sparsely sampled projections of cardiac SPECT. DuDoSS utilized the SPECT images predicted in the image domain as guidance to generate synthetic full‐view projections in the sinogram domain. The synthetic projections were then reconstructed into non‐attenuation‐corrected and attenuation‐corrected (AC) SPECT images for voxel‐wise and segment‐wise quantitative evaluations in terms of normalized mean square error (NMSE) and absolute percent error (APE). Previous deep‐learning‐based approaches, including direct sinogram generation (Direct Sino2Sino) and direct image prediction (Direct Img2Img), were tested in this study for comparison. The dataset used in this study included a total of 500 anonymized clinical stress‐state MPI studies acquired on a GE NM/CT 850 scanner with 60 projection angles following the injection of 99mTc‐tetrofosmin.Results: Our proposed DuDoSS generated more consistent synthetic projections and SPECT images with the ground truth than other approaches. The average voxel‐wise NMSE between the synthetic projections by DuDoSS and the ground‐truth full‐view projections was 2.08% ± 0.81%, as compared to 2.21% ± 0.86% (p < 0.001) by Direct Sino2Sino. The averaged voxel‐wise NMSE between the AC SPECT images by DuDoSS and the ground‐truth AC SPECT images was 1.63% ± 0.72%, as compared to 1.84% ± 0.79% (p < 0.001) by Direct Sino2Sino and 1.90% ± 0.66% (p < 0.001) by Direct Img2Img. The averaged segment‐wise APE between the AC SPECT images by DuDoSS and the ground‐truth AC SPECT images was 3.87% ± 3.23%, as compared to 3.95% ± 3.21% (p = 0.023) by Direct Img2Img and 4.46% ± 3.58% (p < 0.001) by Direct Sino2Sino.Conclusions: Our proposed DuDoSS is feasible to generate accurate synthetic full‐view projections from sparsely sampled projections for cardiac SPECT. The synthetic projections and reconstructed SPECT images generated from DuDoSS are more consistent with the ground‐truth full‐view projections and SPECT images than other approaches. DuDoSS can potentially enable fast data acquisition of cardiac SPECT.Keywords
Funding Information
- National Institutes of Health (R01HL154345)
This publication has 54 references indexed in Scilit:
- Improved Compressed Sensing-Based Algorithm for Sparse-View CT Image ReconstructionComputational and Mathematical Methods in Medicine, 2013
- ‘I thought it was just an x-ray’Nuclear Medicine Communications, 2012
- Stress/Rest Myocardial Perfusion Abnormalities by Gated SPECT: Still the Best Predictor of Cardiac Events in Stable Ischemic Heart DiseaseJournal of Nuclear Medicine, 2009
- Attenuation Correction in Myocardial Perfusion SPECT/CT: Effects of Misregistration and Value of ReregistrationJournal of Nuclear Medicine, 2007
- Correspondence between left ventricular 17 myocardial segments and coronary arteriesEuropean Heart Journal, 2005
- Image quality assessment: from error visibility to structural similarityIEEE Transactions on Image Processing, 2004
- Understanding the humanistic interaction with medical imaging technologyRadiography, 2001
- Maximum-likelihood expectation-maximization reconstruction of sinograms with arbitrary noise distribution using NEC-transformationsIEEE Transactions on Medical Imaging, 2001
- A New Instrument to Measure Patient Satisfaction with MammographyMedical Care, 1997
- Penalized weighted least-squares image reconstruction for positron emission tomographyIEEE Transactions on Medical Imaging, 1994