High-resolution corneal topography and tomography of fish eye using wide-field white light interference microscopy
Authors:
- 15 April 2013
- journal article
- conference paper
- Published by AIP Publishing in Applied Physics Letters
- Vol. 102 (15) , 153701
Abstract
Topography and tomography of fish cornea is reconstructed using high resolution white light interference microscopy. White light interferograms at different depths were recorded by moving the object axially. For each depth position, five phase shifted interferograms were recorded and analyzed. From the reconstructed phase maps, the corneal topography and hence the refractive index was determined and from amplitude images the cross-sectional image of fish cornea was reconstructed. In the present method, we utilize a nearly common-path interference microscope and wide field illumination and hence do not require any mechanical B-scan. Therefore, the phase stability of the recorded data is improved.Keywords
This publication has 31 references indexed in Scilit:
- Scientific and Engineering Applications of Full-field Swept-source Optical Coherence TomographyJournal of the Optical Society of Korea, 2009
- Anterior segment imaging with Spectral OCT system using a high-speed CMOS cameraOptics Express, 2009
- Spectral Optical Coherence TomographyCornea, 2006
- Phase-crossing algorithm for white-light fringes analysisOptics Communications, 2006
- Ultrahigh-resolution high-speed retinal imaging using spectral-domain optical coherence tomographyOptics Express, 2004
- Ultrahigh-resolution, high-speed, Fourier domain optical coherence tomography and methods for dispersion compensationOptics Express, 2004
- Initiation of Gastrulation in the Mouse Embryo Is Preceded by an Apparent Shift in the Orientation of the Anterior-Posterior AxisCurrent Biology, 2004
- Parallel optical coherence tomography in scattering samples using a two-dimensional smart-pixel detector arrayOptics Communications, 2002
- Minimum Lp-norm two-dimensional phase unwrappingJournal of the Optical Society of America A, 1996
- Optical coherence tomographyJournal of Biomedical Optics, 1996