Effect of polyethylene glycol molecular weights and concentrations on polyethersulfone hollow fiber ultrafiltration membranes
- 16 January 2004
- journal article
- research article
- Published by Wiley in Journal of Applied Polymer Science
- Vol. 91 (5) , 3398-3407
Abstract
Polyethersulfone (PES) hollow‐fiber membranes were fabricated using poly(ethyleneglycol) (PEG) with different molecular weights (MW = PEG200, PEG600, PEG2000, PEG6000, and PEG10000) and poly(vinyl pyrrolidone) PVP40000 as additives and N‐methyl‐2‐pyrrolidone (NMP) as a solvent. Asymmetric hollow‐fiber membranes were spun by a wet phase‐inversion method from 25 wt % solids of 20 : 5 : 75 (weight ratio) PES/PEG/NMP or 18 : 7 : 75 of PES/(PEG600 + PVP40000)/NMP solutions, whereas both the bore fluid and the external coagulant were water. Effects of PEG molecular weights and PEG600 concentrations in the dope solution on separation properties, morphology, and mechanical properties of PES hollow‐fiber membranes were investigated. The membrane structures of PES hollow‐fiber membranes including cross section, external surface, and internal surface were characterized by scanning electron microscopy and the mechanical properties of PES hollow‐fiber membranes were discussed. Bovine serum albumin (BSA, MW 67,000), chicken egg albumin (CEA, MW 45,000), and lysozyme (MW 14,400) were used for the measurement of rejection. It was found that with an increase of PEG molecular weights from 200 to 10,000 in the dope solution, membrane structures were changed from double‐layer fingerlike structure to voids in the shape of spheres or ellipsoids; moreover, there were crack phenomena on the internal surfaces and external surfaces of PES hollow‐fiber membranes, pure water permeation fluxes increased from 22.0 to 64.0 L m−2 h−1 bar−1, rejections of three protein for PES/PEG hollow‐fiber membranes were not significant, and changes in mechanical properties were decreased. Besides, with a decrease of PEG600 concentrations in the dope solution, permeation flux and elongation at break decreased, whereas the addition of PVP40000 in the dope solution resulted in more smooth surfaces (internal or external) of PES/(PEG600 + PVP40000) hollow‐fiber membranes than those of PES/PEG hollow‐fiber membranes. © 2004 Wiley Periodicals, Inc. J Appl Polym Sci 91: 3398–3407, 2004Keywords
This publication has 17 references indexed in Scilit:
- Poly(vinyl chloride) (PVC) hollow fiber ultrafiltration membranes prepared from PVC/additives/solventJournal of Membrane Science, 2002
- Polymeric asymmetric membranes made from polyetherimide/polybenzimidazole/poly(ethylene glycol) (PEI/PBI/PEG) for oil–surfactant–water separationJournal of Membrane Science, 1999
- Effect of nonsolvents on properties of spinning solutions and polyethersulfone hollow fiber ultrafiltration membranesJournal of Membrane Science, 1999
- Effect of PEG additive on membrane formation by phase inversionJournal of Membrane Science, 1998
- Formation of ultrathin high-performance polyethersulfone hollow-fiber membranesJournal of Membrane Science, 1997
- The Effect of Polyethersulfone Concentration on Flat and Hollow Fiber Membrane PerformanceSeparation Science and Technology, 1993
- Effect of poly(vinylpyrrolidone) additive on the performance of poly(ether sulfone) ultrafiltration membranesIndustrial & Engineering Chemistry Research, 1987
- Polysulfone ultrafiltration membranesIndustrial & Engineering Chemistry Product Research and Development, 1983
- The effect of low molecular weight additives on the properties of aromatic polyamide membranesJournal of Applied Polymer Science, 1979
- Polysulfone hollow fibers. I. Spinning and propertiesJournal of Applied Polymer Science, 1976