A Novel Pulse Measurement System by Using Laser Triangulation and a CMOS Image Sensor
Authors:
Open Access
- 19 December 2007
- Vol. 7 (12) , 3366-3385
Abstract
This paper presents a novel, non-invasive, non-contact system to measure pulsewaveforms of artery via applying laser triangulation method to detect skin surfacevibration. The proposed arterial pulsation measurement (APM) system chiefly consists of alaser diode and a low cost complementary metal-oxide semiconductor (CMOS) imagesensor. Laser triangulation and centroid method are combined with the Fast FourierTransform (FFT) in this study. The shape and frequency of the arterial pulsation can bedetected rapidly by using our APM system. The relative variation of the pulse at differentmeasurement points near wrist joint is used as a prognostic guide in traditional Chinesemedicine (TCM). An extensive series of experiments was conducted to evaluate theperformance of the designed APM system. From experimental results, the pulse amplitudeand frequency at the Chun point (related to the small intestine) of left hand showed anobvious increase after having food. In these cases, the peak to peak amplitudes and thefrequencies of arterial pulsations range from 38 to 48 μm and from 1.27 to 1.35 Hz,respectively. The height of arterial pulsations on the area near wrist joint can be estimatedwith a resolution of better than 4 μm. This research demonstrates that applying a CMOSimage sensor in designing a non-contact, portable, easy-to-use, low cost pulse measurementsystem is feasible. Also, the designed APM system is well suited for evaluating and pre-diagnosing the health of a human being in TCM clinical practice.Keywords
This publication has 14 references indexed in Scilit:
- Electro-optical leveler using a bowl-shaped lensOptical Engineering, 2006
- Measurement of human vocal fold vibrations with laser triangulationOptical Engineering, 2001
- Laser ranging: a critical review of usual techniques for distance measurementOptical Engineering, 2001
- Pulse analysis of patients with severe liver problems. Studying pulse spectrums to determine the effects on other organsIEEE Engineering in Medicine and Biology Magazine, 1999
- Technology and device scaling considerations for CMOS imagersIEEE Transactions on Electron Devices, 1996
- 3D environment modelling using laser range sensingRobotics and Autonomous Systems, 1995
- Laser triangulation: fundamental uncertainty in distance measurementApplied Optics, 1994
- No touch pulse measurement by optical interferometryIEEE Transactions on Biomedical Engineering, 1994
- Application of pattern recognition and image classification techniques to determine continuous cardiac output from the arterial pressure waveformIEEE Transactions on Biomedical Engineering, 1994
- An Objective Method of Pulse DiagnosisThe American Journal of Chinese Medicine, 1987