Verification of dynamic radiotherapy: the potential for 3D dosimetry under respiratory-like motion using polymer gel
Authors:
- S CebergSCS Ceberg
- A KarlssonAKA Karlsson
- H GustavssonHGH Gustavsson
- L WittgrenLWL Wittgren
- S Å J BäckSBS Å J Bäck
- 30 September 2008
- journal article
- research article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 53 (20) , N387-N396
Abstract
Following the implementation of advanced treatment procedures in radiotherapy, there is a need for dynamic dose verification in 3D. Gel dosimetry could potentially be used for such measurements. However, recently published data show that certain types of gels have a dose rate and fractionation dependence. The aim of this study was to investigate the feasibility of using a polymer gel dosimeter for dose verification of dynamic radiotherapy. To investigate the influence of dose rate dependence during respiratory-like motion in and out of the beam, a respiration robot together with two types of gel systems (normoxic methacrylic acid gel (nMAG) and normoxic polyacrylamide gel (nPAG)) were used. Reference measurements were obtained using a linear diode array (LDA). Expected results, if there was no influence of the dose rate variation, were calculated by convolving the static irradiated gel data with the motion function controlling the robot. To investigate the fractionation dependence, the gels were irradiated using gated and ungated deliveries. Magnetic resonance imaging was used to evaluate the absorbed dose response of the gel. The measured gel data coincided well with the LDA data. Also, the calculated data agreed well with the measured dynamic gel data, i.e. no dose rate dependence due to motion was observed. The difference in the R2 response for the gels receiving ungated and gated, i.e. fractionated, deliveries was less than 1% for the nPAG and 4% for the nMAG, for absorbed doses up to 2 Gy. The maximum difference was 1.2% for the nPAG and 9% for the nMAG, which occurred at the highest given dose (4 Gy). The investigated gels were found to be feasible detectors for dose measurements under respiratory-like motion. For dose verification of dynamic RT involving gated delivery, e.g. breathing-adapted radiotherapy, relative absorbed dose evaluation should be used in order to minimize the effects of fractionated irradiation.Keywords
This publication has 14 references indexed in Scilit:
- Advances in 4D Medical Imaging and 4D Radiation TherapyTechnology in Cancer Research & Treatment, 2008
- Dose integration characteristics in normoxic polymer gel dosimetry investigated using sequential beam irradiationPhysics in Medicine & Biology, 2007
- Gamma Knife 3‐D dose distribution near the area of tissue inhomogeneities by normoxic gel dosimetryMedical Physics, 2007
- Geometric accuracy of a real-time target tracking system with dynamic multileaf collimator tracking systemInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2006
- Dosimetric and radiobiological impact of dose fractionation on respiratory motion induced IMRT delivery errors: A volumetric dose measurement studyMedical Physics, 2006
- The fundamental radiation properties of normoxic polymer gel dosimeters: a comparison between a methacrylic acid based gel and acrylamide based gelsPhysics in Medicine & Biology, 2006
- Technical and dosimetric aspects of respiratory gating using a pressure‐sensor motion monitoring systemMedical Physics, 2005
- Modeling of Free‐radical Crosslinking Copolymerization of Acrylamide and N,N′‐Methylenebis(acrylamide) for Radiation DosimetryMacromolecular Theory and Simulations, 2003
- MAGIC‐type polymer gel for three‐dimensional dosimetry: Intensity‐modulated radiation therapy verificationMedical Physics, 2003
- Gel dosimetry for the dose verification of Intensity Modulated Radiotherapy TreatmentsZeitschrift für Medizinische Physik, 2002