Differences in Measurement of Lower Limb Alignment Among Different Registration Methods of Navigation and Radiographs in TKA Using the OrthoPilot System
Authors:
- Seung-Suk SeoSSSeung-Suk Seo
- Jin-Hyeok SeoJSJin-Hyeok Seo
- Myung-Whan SohnMSMyung-Whan Sohn
- Yoon-Jun KimYKYoon-Jun Kim
- 1 October 2012
- journal article
- research article
- Published by SLACK, Inc. in Orthopedics
- Vol. 35 (10) , 50-55
Abstract
The purposes of this study were (1) to compare lower limb alignment measurements between radiographs and computer-assisted surgery and (2) to evaluate the discrepancy in lower limb alignment between computer-assisted surgery with a high tibial osteotomy protocol and computer-assisted surgery with a total knee arthroplasty (TKA) protocol in the same knee. Seventy-one TKAs were performed on patients with primary osteoarthritis using computer-assisted surgery. Preoperative lower limb alignment was measured using the mechanical axis during bipedal, weight-bearing, whole-leg anteroposterior radiography (measure 1). The intraoperative mechanical axis was measured with computer-assisted surgery according to the high tibial osteotomy protocol before joint exposure (measure 2). After changing the software and joint exposure, the intraoperative mechanical axis was measured with computer-assisted surgery according to TKA protocol (measure 3). After final TKA implantation, the lower limb mechanical axis was measured with computer-assisted surgery following the TKA protocol (measure 4). Postoperative lower limb alignment was measured using the mechanical axis on whole-leg standing anteroposterior radiographs (measure 5). The mechanical axis and median value from each group were compared. Factors affecting the mechanical axis measurement were also analyzed. The difference in the mechanical axis between measures 1 and 2, measures 1 and 3, and measures 2 and 3 was significant ( P <.0001, <.0001, and =.0007, respectively). The difference between measures 4 and 5 was also significant ( P <.0001). Factors affecting the mechanical axis measurement, such as age, height, weight, and range of motion, showed no correlation ( R 2 =.07244 and adjusted R 2 =.01622). The pre- and postoperative radiological measurements of limb alignment using the mechanical axis were different from the intraoperative measurements with navigation.Keywords
This publication has 15 references indexed in Scilit:
- Comparison of Standard Anteroposterior Knee and Hip-to-Ankle Radiographs in Determining the Lower Limb and Implant Alignment after Total Knee ArthroplastyScandinavian Journal of Surgery, 2009
- Comparison of Computer-Assisted Navigation and Conventional Instrumentation for Bilateral Total Knee ArthroplastyThe Journal of Arthroplasty, 2009
- Computer-Assisted Surgical Navigation Does Not Improve the Alignment and Orientation of the Components in Total Knee ArthroplastyJournal of Bone and Joint Surgery, 2009
- Initial Experience With Electromagnetic Navigation in Total Knee Arthroplasty – A Radiographic Comparative StudyThe Journal of Knee Surgery, 2007
- Computer-Assisted Surgery versus Manual Total Knee Arthroplasty: A Case-Controlled StudyJournal of Bone and Joint Surgery, 2006
- Femoral stress fracture after computer navigated total knee arthroplastyThe Knee, 2006
- Computer Assisted Navigation in Total Knee ArthroplastyThe Journal of Arthroplasty, 2005
- Navigated intraoperative analysis of lower limb alignmentArchives of orthopaedic and trauma surgery, 2005
- Alignment in total knee arthroplastyThe Journal of Bone and Joint Surgery. British volume, 2004
- Survival of knee arthroplasties. A nation-wide multicentre investigation of 8000 casesThe Journal of Bone and Joint Surgery. British volume, 1986