Intraocular lenses with surface aspherization: Interferometric study
Authors:
- Rita MencucciRMRita Mencucci
- Ugo MenchiniUMUgo Menchini
- Roberto VolpeRVRoberto Volpe
- Maurizio VannoniMVMaurizio Vannoni
- Giuseppe MolesiniGMGiuseppe Molesini
- 1 September 2007
- journal article
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 33 (9) , 1624-1630
Abstract
To accurately evaluate in an optical laboratory 2 different types of intraocular lenses (IOLs). Department of Oto-Neuro-Ophthalmological Surgical Sciences and CNR-Institute for Applied Optics, Florence Italy. In this study, optical testing facilities based on interferometry were used. The IOLs were inspected with laser light, and interference patterns were acquired and processed, obtaining the physical parameters accounting for the lens behavior. Comparison of the respective performances within the pseudophakic eye was provided in terms of modulation transfer function (MTF) using lens diameters from 3.0 mm to 5.0 mm. The data were inserted in a mathematical model of the eye, and the relevant merit functions were computed with a ray-tracing program. Sample sets of both all-spherical IOLs and IOLs with aspherical surfaces were inspected. The interferometric maps showed clear evidence of the opposite wave aberration introduced by the different IOL types. With a 3.0 mm pupil diameter, both IOL types performed as almost ideal lenses, while with a 5.0 mm diameter, IOLs with aspherical surfaces effectively compensated for the spherical aberration of the cornea and had a significantly higher MTF. The interferometric approach to IOL testing provided accurate data on the physical parameters of the IOL. With a measuring and computing chain that includes eye modeling and ray tracing, it was possible to analyze in detail the process by which IOLs with aspherical surfaces compensate for the spherical aberration of the cornea under photopic, mesopic, and scotopic conditions.Keywords
This publication has 30 references indexed in Scilit:
- Intraocular lens to correct corneal comaOptics Letters, 2007
- Optical aberrations of the cornea and the crystalline lensOptik, 2006
- Spherical aberration of the anterior and posterior surfaces of the human corneaJournal of the Optical Society of America A, 2006
- Optics of the average normal cornea from general and canonical representations of its surface topographyJournal of the Optical Society of America A, 2006
- Optical aberrations of intraocular lenses measured in vivo and in vitroJournal of the Optical Society of America A, 2003
- Impact of a modified optic design on visual function: Clinical comparative studyJournal of Cataract & Refractive Surgery, 2003
- Contribution of the cornea and internal surfaces to the change of ocular aberrations with ageJournal of the Optical Society of America A, 2002
- Optical aberrations of the human cornea as a function of ageJournal of the Optical Society of America A, 2000
- Design of aspheric intraocular lensesOphthalmic and Physiological Optics, 1991
- The aspherizing of intra‐ocular lensesOphthalmic and Physiological Optics, 1990