Experimental Study on the Aerodynamic Sealing of Air Curtains
Open Access
Abstract
Controlling the air quality is of the utmost importance in today’s buildings. Vertical air curtains are often used to separate two different climatic zones with a view to reduce heat transfer. In fact, this research work proposes an air curtain aimed to ensure a proper separation between two zones, a clean one and a contaminated one. The methodology of this research includes: (i) small-scale tests on water models to ensure that the contamination does not pass through the air curtain, and (ii) an analytical development integrating the main physical characteristics of plane jets. In the solution developed, the airflow is extracted from the contaminated compartment to reduce the curtain airflow rejected to the exterior of the compartment. In this research work, it was possible to determine the minimum exhaust flow necessary to ensure the aerodynamic sealing of the air curtain. This article addresses the methodology used to perform the small-scale water tests and the corresponding results.Keywords
All Related Versions
Funding Information
- H2020 Industrial Leadership (Marie Sklodowska-Curie grant agreement N 690968)
This publication has 18 references indexed in Scilit:
- Assessing dynamic efficiency of air curtain in reducing whole building annual energy usageBuilding Simulation, 2017
- Saltwater experiments with air curtains for smoke control in the event of fireJournal of Building Engineering, 2016
- Experimental study on the flow characteristics of air curtains at building entrancesBuilding and Environment, 2016
- Efficacy of an air curtain system for local pit environmental control for relic preservation in archaeology museumsIndoor and Built Environment, 2015
- Simulation-based feasibility study of improved air conditioning systems for hospital operating roomFrontiers of Architectural Research, 2013
- CFD modelling of aerodynamic sealing by vertical and horizontal air curtainsEnergy and Buildings, 2012
- Predictions and measurements of the stack effect on indoor airborne virus transmission in a high-rise hospital buildingBuilding and Environment, 2011
- Using air curtain to control pollutant spreading for emergency management in a cleanroomBuilding and Environment, 2011
- Energy savings by aerodynamic sealing with a downward-blowing plane air curtain—A numerical approachEnergy and Buildings, 2006
- Performance of ventilation system in a non-standard operating roomBuilding and Environment, 2003