External validation of a convolutional neural network algorithm for opportunistically detecting vertebral fractures in routine CT scans
Authors:
Open Access
- 7 September 2023
- journal article
- research article
- Published by Springer Nature in Osteoporosis International
- Vol. 35 (1) , 143-152
Abstract
Summary The Convolutional Neural Network algorithm achieved a sensitivity of 94% and specificity of 93% in identifying scans with vertebral fractures (VFs). The external validation results suggest that the algorithm provides an opportunity to aid radiologists with the early identification of VFs in routine CT scans of abdomen and chest. Purpose To evaluate the performance of a previously trained Convolutional Neural Network (CNN) model to automatically detect vertebral fractures (VFs) in CT scans in an external validation cohort. Methods Two Chinese studies and clinical data were used to retrospectively select CT scans of the chest, abdomen and thoracolumbar spine in men and women aged ≥50 years. The CT scans were assessed using the semiquantitative (SQ) Genant classification for prevalent VFs in a process blinded to clinical information. The performance of the CNN model was evaluated against reference standard readings by the area under the receiver operating characteristics curve (AUROC), accuracy, Cohen’s kappa, sensitivity, and specificity. Results A total of 4,810 subjects were included, with a median age of 62 years (IQR 56-67), of which 2,654 (55.2%) were females. The scans were acquired between January 2013 and January 2019 on 16 different CT scanners from three different manufacturers. 2,773 (57.7%) were abdominal CTs. A total of 628 scans (13.1%) had ≥1 VF (grade 2-3), representing 899 fractured vertebrae out of a total of 48,584 (1.9%) visualized vertebral bodies. The CNN’s performance in identifying scans with ≥1 moderate or severe fractures achieved an AUROC of 0.94 (95% CI: 0.93-0.95), accuracy of 93% (95% CI: 93%-94%), kappa of 0.75 (95% CI: 0.72-0.77), a sensitivity of 94% (95% CI: 92-96%) and a specificity of 93% (95% CI: 93-94%). Conclusion The algorithm demonstrated excellent performance in the identification of vertebral fractures in a cohort of chest and abdominal CT scans of Chinese patients ≥50 years. Graphical abstractKeywords
This publication has 31 references indexed in Scilit:
- Intra and Interobserver Reliability and Agreement of Semiquantitative Vertebral Fracture Assessment on Chest Computed TomographyPLOS ONE, 2013
- The Design of SimpleITKFrontiers in Neuroinformatics, 2013
- Osteoporosis Imaging: State of the Art and Advanced ImagingRadiology, 2012
- Incidental vertebral compression fractures in imaging studies: Lessons not learned by radiologistsWorld Journal of Radiology, 2010
- Algorithm-Based Qualitative and Semiquantitative Identification of Prevalent Vertebral Fracture: Agreement Between Different Readers, Imaging Modalities, and Diagnostic ApproachesJournal of Bone and Mineral Research, 2008
- User-guided 3D active contour segmentation of anatomical structures: Significantly improved efficiency and reliabilityNeuroImage, 2006
- Osteoporosis: A still increasing prevalenceBone, 2006
- Sample size calculation should be performed for design accuracy in diagnostic test studiesJournal of Clinical Epidemiology, 2005
- Vertebral fracture assessment using a semiquantitative techniqueJournal of Bone and Mineral Research, 1993
- Incidence of clinically diagnosed vertebral fractures: A population-based study in rochester, minnesota, 1985-1989Journal of Bone and Mineral Research, 1992