Background: Cardiovascular morbidity and mortality was reduced by 25% when blood pressure ( BP ) was targeted to 120 mm Hg systolic compared with 140 mm Hg systolic in Systolic Blood Pressure Intervention Trial (SPRINT); however, BP was measured using a research technique. SPRINT specified 5 minutes of seated rest in a quiet room followed by 3 oscillometric measurements without an observer in the room. The relationship of this research‐grade methodology to routine BP measurements is not known. Methods and Results: Among 275 people with chronic kidney disease who had BP <140/90 mm Hg when they came to the clinic, we measured BP as in SPRINT and recorded BP on the same day without specification of seated rest. Compared with routine measurement, the research‐grade systolic BP was 12.7 mm Hg lower with wide limits of agreement (−46.1 to 20.7 mm Hg). Research grade systolic BP was 7.9 mm Hg lower than daytime ambulatory systolic BP and had wide agreement limits (−33.2 to 17.4 mm Hg). Whereas the routine, research‐grade, and daytime ambulatory systolic BP were all related to echocardiographic left ventricular hypertrophy, the strength of the relationship between research‐grade and daytime ambulatory systolic BP to left ventricular hypertrophy was similar and stronger than the strength of the relationship between routine systolic BP and left ventricular hypertrophy. Conclusions: Taken together, these results suggest that translation of the SPRINT results will require measurement of BP as performed in that trial. Instead of an algebraic manipulation of routine clinic measurements, the SPRINT methodology of BP measurement would be needed at minimum if implementation of the SPRINT results were to be deployed in the population at large.Keywords
This publication has 21 references indexed in Scilit:
- Blood-pressure targets in patients with recent lacunar stroke: the SPS3 randomised trialThe Lancet, 2013
- The great myth of office blood pressure measurementJournal Of Hypertension, 2012
- Blood pressure rising: differences between current clinical and recommended measurement techniquesJournal of the American Society of Hypertension, 2011
- Conventional versus automated measurement of blood pressure in primary care patients with systolic hypertension: randomised parallel design controlled trialBMJ, 2011
- Effects of Intensive Blood-Pressure Control in Type 2 Diabetes MellitusThe New England journal of medicine, 2010
- Reliability and validity of blood pressure measurement in the Secondary Prevention of Small Subcortical Strokes studyBlood Pressure Monitoring, 2007
- Accuracy of the SpaceLabs 90207 determined by the British Hypertension Society ProtocolJournal Of Hypertension, 1991
- Echocardiographic assessment of left ventricular hypertrophy: Comparison to necropsy findingsThe American Journal of Cardiology, 1986
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986
- Recommendations regarding quantitation in M-mode echocardiography: results of a survey of echocardiographic measurements.Circulation, 1978