Prospective randomised controlled trial comparing PLLA and PLDLA/HA/β‐TCP interference screws in anterior cruciate ligament reconstruction: CT scans, MRI and clinical outcomes
Authors:
Open Access
- 9 September 2025
- journal article
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 34 (7) , 2408-2417
Abstract
Purpose: Modifying interference screw composition may ensure better osteoconductive properties in order to reduce tunnel enlargement after anterior cruciate ligament (ACL) reconstruction. The primary and secondary purposes were to evaluate tunnel and screw volume changes in poly‐L‐lactide acid (PLLA) and poly‐D‐lactic acid + hydroxyapatite + β‐tricalcium phosphate (PLDLA+) screws. The tertiary purpose was to compare patient reported‐ and functional outcomes between PLLA and PLDLA+ group. It was hypothesised that PLLA group would show more tunnel enlargement and a lower rate of resorption than PLDLA+ group with similar clinical results.Methods: Patients were treated with ACL reconstruction using hamstring autograft with femoral and tibial interference screw fixation (PLLA or PLDLA+). Tunnel volume changes were assessed after 0, 24 and 36 months on computed tomography (CT) scans. Screw volume changes were analysed after 0, 3, 6, 12, 24 and 36 months on magnetic resonance imaging (MRI). Patient reported outcome scores (PROMS) and knee laxity were analysed after 12 and 36 months. Data were evaluated using analysis of variance (ANOVA) with Bonferroni correction. Significance was set at n = 9) and 2.6 ± 30.8%/19.0 ± 20.5% (PLDLA +, n = 13) after 36 months on CT scans (p = 0.063/p = 0.070). Using MRI scans, femoral/tibial screw volume decreased −53.8 ± 6.9%/−48.8 ± 9% (PLLA) and −88.2 ± 8.9%/−80.6 ± 3.4% (PLDLA+) (p ≤ 0.001/p ≤ 0.001). No difference was found between the two groups (PLLA, n = 17; PLDLA+, n = 19) in PROMS and knee laxity (n.s. and/or minimal clinically important difference (MCID) not reached).Conclusions: Tunnel volumes remained slightly enlarged, screw degradation was significantly higher in the PLDLA+ group while clinical outcomes led to good short‐term results. Comparable tunnel enlargement for both screws can be expected in revision ACL reconstruction.Level of Evidence: Level 1, RCT.Keywords
This publication has 37 references indexed in Scilit:
- PEEK Interference Screws Show Significant Tunnel Enlargement After ACL Reconstruction and is Comparable to Adjustable-Length Loop Cortical Button FixationIndian Journal of Orthopaedics, 2023
- ACL reconstruction with adjustable-length loop cortical button fixation results in less tibial tunnel widening compared with interference screw fixationKnee Surgery, Sports Traumatology, Arthroscopy, 2019
- A prospective randomized study of ACL‐reconstructions using bone‐patellar tendon‐bone grafts fixed with bioabsorbable or metal interference screwsKnee Surgery, Sports Traumatology, Arthroscopy, 2011
- Comparison of plain radiography, computed tomography, and magnetic resonance imaging in the evaluation of bone tunnel widening after anterior cruciate ligament reconstructionKnee Surgery, Sports Traumatology, Arthroscopy, 2009
- Tibial tunnel widening after bioresorbable poly‐lactide calcium carbonate interference screw usage in ACL reconstructionKnee Surgery, Sports Traumatology, Arthroscopy, 2009
- Poly-L-lactic acid — hydroxyapatite (PLLA-HA) bioabsorbable interference screws for tibial graft fixation in anterior cruciate ligament (ACL) reconstruction surgery: MR evaluation of osteointegration and degradation featuresLa radiologia medica, 2008
- Prospective Evaluation of Patellar Tendon Graft Fixation in Anterior Cruciate Ligament Reconstruction Comparing Composite Bioabsorbable and Allograft Interference ScrewsArthroscopy, 2006
- Long‐Term Absorption of Poly‐L‐Lactic Acid Interference ScrewsArthroscopy, 2006
- The Natural History of a Bioabsorbable Interference Screw Used for Anterior Cruciate Ligament Reconstruction With a 4‐Strand Hamstring TechniqueArthroscopy, 2005
- A prospective randomized comparison of bioabsorbable and titanium anterior cruciate ligament interference screwsArthroscopy, 2005