TSV Based Orthogonal Coils With High Misalignment Tolerance for Inductive Power Transfer in Biomedical Implants
- 31 December 2020
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Circuits and Systems II: Express Briefs
- Vol. 68 (6) , 1832-1836
Abstract
To improve the misalignment tolerance for inductive power transfer (IPT) systems in implantable medical devices, like retinal prosthesis, a 3-D through silicon via (TSV) based orthogonal receiving coil is proposed in this brief. The mutual inductance between the receiving coil and the transmitting coil is calculated, analyzed, and compared. Results obtained from the analytical model and finite element method show the proposed coil structure significantly enhances the inductive coupling between coils under misalignment. Furthermore, we present receiving circuits with current summing techniques to enhance the energy transfer between the receiving coil to the load. The prototype of the inductive power transfer system is developed and the experimental results demonstrate that the proposed coil structure can provide a good misalignment tolerance. A maximum variation of the power transfer efficiency (PTE) is only 18.0% under angular misalignment of 90∘ and 23.4% under lateral misalignment of 37.5% of the transmitting coil’s diameter, which indicates the proposed coil structure can meet the demand of IPT systems in retinal prosthesis applications.Keywords
Funding Information
- National Natural Science Foundation of China (61771268, U1709218, 61871242, 61671257)
- K. C. Wong Magna Fund in Ningbo University
This publication has 27 references indexed in Scilit:
- An Advanced 2.5-D Heterogeneous Integration Packaging for High-Density Neural Sensing MicrosystemIEEE Transactions on Electron Devices, 2017
- Simple and accurate inductance model of 3D inductor based on TSVElectronics Letters, 2016
- Large air gap misalignment tolerable multi‐coil inductive power transfer for wireless sensorsIET Power Electronics, 2016
- EMF Safety and Thermal Aspects in a Pacemaker Equipped With a Wireless Power Transfer System Working at Low FrequencyIEEE Transactions on Microwave Theory and Techniques, 2016
- A Miniaturized, Eye-Conformable, and Long-Term Reliable Retinal Prosthesis Using Monolithic Fabrication of Liquid Crystal Polymer (LCP)IEEE Transactions on Biomedical Engineering, 2014
- An Investigation Into the Use of Orthogonal Winding in Loosely Coupled Link for Improving Power Transfer Efficiency Under Coil MisalignmentIEEE Transactions on Power Electronics, 2014
- A 13.56-Mbps Pulse Delay Modulation Based Transceiver for Simultaneous Near-Field Data and Power TransmissionIEEE Transactions on Biomedical Circuits and Systems, 2014
- Inductor array for minimising transfer efficiency decrease of wireless power transmission components at misalignmentElectronics Letters, 2014
- A Fully-Integrated High-Compliance Voltage SoC for Epi-Retinal and Neural ProsthesesIEEE Transactions on Biomedical Circuits and Systems, 2013
- Orientation insensitive power transfer by magnetic resonance for mobile devices2013