Annuli Liquid-Level Surveillance Using Distributed Fiber-Optic Sensing Data
Open Access
- 11 October 2023
- journal article
- research article
- Published by Society of Petroleum Engineers (SPE) in SPE Journal
- Vol. 29 (02) , 1195-1209
Abstract
Summary: Annular pressure buildup due to fluid expansion can be mitigated by using a compressible fluid, typically nitrogen, as a cushion at the top of an annuli. The advantage of using a nitrogen cushion is that we do not have to manipulate annuli pressures as often during variations in production. A disadvantage is that it is more difficult to detect small leaks to or from an annulus. For gas lift-assisted production wells, Annulus A is used for the transportation of gas down to the gas lift valves (GLVs), effectively making up a large gas cushion compared with the full length for the annulus. In light of this, monitoring annular pressures and ensuring continuous control of fluid volumes are essential for effective well barrier management. We present relevant theory and show that we can track annuli liquid levels using distributed temperature sensing (DTS) and/or distributed acoustic sensing (DAS) data to detect leaks, estimate leak rates, and infer leak paths. We find that the main cause for observing liquid levels in these data is because the equilibrium temperature at the fiber is dependent on the fluid fill of the various annuli in addition to the temperature inside the tubing and outside of the well. Six data examples with variations in liquid level(s) are presented to demonstrate this. Furthermore, simple models for estimating changes in liquid levels are proposed and compared with liquid levels from distributed fiber-optic (FO) data. Being able to detect leaks to or from annuli makes it possible for the operator to apply mitigating action in a timely manner, prevent unwanted well integrity situations, and ensure production regularity.Keywords
This publication has 29 references indexed in Scilit:
- Assessing integrity of the gas-lift valves by analyzing annular-pressure-transient responseJournal of Petroleum Science and Engineering, 2015
- First Real-Time DTS Inversion Job Worldwide2013
- Fluid-Level Monitoring Using a Distributed Temperature Sensing System During a Methane Hydrate Production Test2013
- Transient Behavior of Annular Pressure Build-up in HP/HT WellsSPE Drilling & Completion, 2006
- Slickline With Fiber-Optic Distributed Temperature Monitoring for Water-Injection and Gas Lift Systems Optimization in Mexico2005
- Field Trial Results of Annular Pressure Behavior in a High-Pressure/High-Temperature WellSPE Drilling & Completion, 1995
- Heat transfer in automobile radiators of the tubular typeInternational Communications in Heat and Mass Transfer, 1985
- The Automatic Liquid Level Monitor for Pumping WellsJournal of Petroleum Technology, 1977
- A Correlating Equation for Forced Convection From Gases and Liquids to a Circular Cylinder in CrossflowJournal of Heat Transfer, 1977
- Acoustic Determination of Liquid Levels in Gas WellsJournal of Petroleum Technology, 1967