Clinical and computational development of a patient-calibrated ICGFA bowel transection recommender
Open Access
- 18 April 2024
- journal article
- research article
- Published by Springer Nature in Surgical Endoscopy
- Vol. 38 (6) , 3212-3222
Abstract
Introduction: Intraoperative indocyanine green fluorescence angiography (ICGFA) aims to reduce colorectal anastomotic complications. However, signal interpretation is inconsistent and confounded by patient physiology and system behaviours. Here, we demonstrate a proof of concept of a novel clinical and computational method for patient calibrated quantitative ICGFA (QICGFA) bowel transection recommendation. Methods: Patients undergoing elective colorectal resection had colonic ICGFA both immediately after operative commencement prior to any dissection and again, as usual, just before anastomotic construction. Video recordings of both ICGFA acquisitions were blindly quantified post hoc across selected colonic regions of interest (ROIs) using tracking-quantification software and computationally compared with satisfactory perfusion assumed in second time-point ROIs, demonstrating 85% agreement with baseline ICGFA. ROI quantification outputs detailing projected perfusion sufficiency-insufficiency zones were compared to the actual surgeon-selected transection/anastomotic construction site for left/right-sided resections, respectively. Anastomotic outcomes were recorded, and tissue lactate was also measured in the devascularised colonic segment in a subgroup of patients. The novel perfusion zone projections were developed as full-screen recommendations via overlay heatmaps. Results: No patient suffered intra- or early postoperative anastomotic complications. Following computational development (n = 14) the software recommended zone (ROI) contained the expert surgical site of transection in almost all cases (Jaccard similarity index 0.91) of the nine patient validation series. Previously published ICGFA time-series milestone descriptors correlated moderately well, but lactate measurements did not. High resolution augmented reality heatmaps presenting recommendations from all pixels of the bowel ICGFA were generated for all cases. Conclusions: By benchmarking to the patient’s own baseline perfusion, this novel QICGFA method could allow the deployment of algorithmic personalised NIR bowel transection point recommendation in a way fitting existing clinical workflow.Keywords
Funding Information
- Derpartment of Enterprise, Trade and Employment (DTIF (Disruptive Technologies Innovation Fund))
- Ministry for Education, Sport, Youth, Research and Innovation (TESS - Tertiary Education Scholarship Scheme)
- University College Dublin
This publication has 42 references indexed in Scilit:
- Cost analysis of indocyanine green fluorescence angiography for prevention of anastomotic leakage in colorectal surgerySurgical Endoscopy, 2022
- The use of tissue oxygen measurements compared to indocyanine green imaging for the assessment of intraoperative tissue viability of human bowelSurgical Endoscopy, 2021
- Inter-user variation in the interpretation of near infrared perfusion imaging using indocyanine green in colorectal surgerySurgical Endoscopy, 2021
- Computer-assisted quantification and visualization of bowel perfusion using fluorescence-based enhanced reality in left-sided colonic resectionsSurgical Endoscopy, 2020
- Quantification of fluorescence angiography: Toward a reliable intraoperative assessment of tissue perfusion - A narrative reviewLangenbeck's Archives of Surgery, 2020
- Intraoperative angiography with indocyanine green to assess anastomosis perfusion in patients undergoing laparoscopic colorectal resection: results of a multicenter randomized controlled trialSurgical Endoscopy, 2019
- Quantitative analysis of colon perfusion pattern using indocyanine green (ICG) angiography in laparoscopic colorectal surgerySurgical Endoscopy, 2018
- ICG fluorescence imaging for quantitative evaluation of colonic perfusion in laparoscopic colorectal surgerySurgical Endoscopy, 2017
- Intraoperative fluorescence-based enhanced reality laparoscopic real-time imaging to assess bowel perfusion at the anastomotic site in an experimental modelBritish Journal of Surgery, 2015
- Near-infrared (NIR) perfusion angiography in minimally invasive colorectal surgerySurgical Endoscopy, 2014