Static and Dynamic Cerclage Wire Analysis
Authors:
- 1 March 1986
- journal article
- research article
- Published by Wiley in Veterinary Surgery
- Vol. 15 (2) , 181-184
Abstract
A new type of double loop cerclage wire, conventional single wire loop cerclage, and twist‐type cerclage were evaluated. The double loop cerclage was applied using the Osteo Systems double loop tightener. Two groups of single wire loop cerclage were applied using the Osteo System loop tightener and the Richards loop tightener. Two groups of twist‐type cerclage were applied using the Kirschner wire twister and side‐cutting pliers. The test system allowed determination of the static tension produced by each wire, as weH as its ability to resist distraction. The double loop cerclage wires were the most effective in producing static tension and in resisting distraction. While the conventional single loop cerclage wires produced more static tension than the twist cerclage wires, they were less effective in resisting distraction.Keywords
This publication has 8 references indexed in Scilit:
- Resistance of cerclage to knot failureJournal of the American Veterinary Medical Association, 1985
- In Vitro Cerclage Wiring AnalysisVeterinary Surgery, 1982
- The Effects of Cerclage Wiring on the Immature Canine Diaphysis A Biomechanical AnalysisVeterinary Surgery, 1982
- Use and Misuse of Full Cerclage Wires in Fracture RepairVeterinary Clinics of North America, 1978
- Effective Use of Cerclage in the Treatment of Long-Bone Fractures in DogsJournal of the American Veterinary Medical Association, 1975
- Fracture Nonunion Resulting from Cerclage AppliancesJournal of the American Veterinary Medical Association, 1974
- Some Aspects of the Microcirculation of Healing BoneClinical Orthopaedics and Related Research, 1965
- Instruments for Use with Flexible Steel Wire in Bone SurgeryJournal of Bone and Joint Surgery, 1958