Provider risk factors for medication administration error alerts: analyses of a large‐scale closed‐loop medication administration system using RFID and barcode
Authors:
- 27 July 2016
- journal article
- research article
- Published by Wiley in Pharmacoepidemiology and Drug Safety
- Vol. 25 (12) , 1387-1396
Abstract
Purpose: To determine the risk factors and rate of medication administration error (MAE) alerts by analyzing large‐scale medication administration data and related error logs automatically recorded in a closed‐loop medication administration system using radio‐frequency identification and barcodes.Methods: The subject hospital adopted a closed‐loop medication administration system. All medication administrations in the general wards were automatically recorded in real‐time using radio‐frequency identification, barcodes, and hand‐held point‐of‐care devices. MAE alert logs recorded during a full 1 year of 2012. We evaluated risk factors for MAE alerts including administration time, order type, medication route, the number of medication doses administered, and factors associated with nurse practices by logistic regression analysis.Results: A total of 2 874 539 medication dose records from 30 232 patients (882.6 patient‐years) were included in 2012. We identified 35 082 MAE alerts (1.22% of total medication doses). The MAE alerts were significantly related to administration at non‐standard time [odds ratio (OR) 1.559, 95% confidence interval (CI) 1.515–1.604], emergency order (OR 1.527, 95%CI 1.464–1.594), and the number of medication doses administered (OR 0.993, 95%CI 0.992–0.993). Medication route, nurse's employment duration, and working schedule were also significantly related.Conclusion: The MAE alert rate was 1.22% over the 1‐year observation period in the hospital examined in this study. The MAE alerts were significantly related to administration time, order type, medication route, the number of medication doses administered, nurse's employment duration, and working schedule. The real‐time closed‐loop medication administration system contributed to improving patient safety by preventing potential MAEs. Copyright © 2016 John Wiley & Sons, Ltd.Keywords
Funding Information
- Ministry of Health & Welfare, Republic of Korea (HI14C3201)
This publication has 30 references indexed in Scilit:
- Are interventions to reduce interruptions and errors during medication administration effective?: a systematic reviewBMJ Quality & Safety, 2013
- t-tests, non-parametric tests, and large studies—a paradox of statistical practice?BMC Medical Research Methodology, 2012
- Effect of Bar-Code Technology on the Safety of Medication AdministrationNew England Journal of Medicine, 2010
- Medication errors: prevention using information technology systemsBritish Journal of Clinical Pharmacology, 2009
- Workarounds to Barcode Medication Administration Systems: Their Occurrences, Causes, and Threats to Patient SafetyJournal of the American Medical Informatics Association, 2008
- The impact of a closed-loop electronic prescribing and administration system on prescribing errors, administration errors and staff time: a before-and-after studyQuality and Safety in Health Care, 2007
- Using bar-code technology and medication observation methodology for safer medication administrationAmerican Journal of Health-System Pharmacy, 2007
- Nursing Home Error and Level of Staff CredentialsClinical Nursing Research, 2007
- Medication ErrorsJournal of Infusion Nursing, 2005
- Drug-Related Problems in Hospitalised PatientsDrug Safety, 2000