Abstract
Cu–Pd and Cu–Pd–Ag alloys can find application as corrosion-resistant conductors of weak electrical signals. The work is devoted to the comparison of the structure and physical and mechanical properties of copper, Cu–8Pd and Cu–8Pd–3Ag alloys (at %). Samples in various initial states were studied: quenched and deformed, and annealed at temperatures ranging from 150 to 450°C. Heat treatment durations ranged from 0.5 to 216 h. It has been established that in almost the entire range of annealing temperatures, the electrical resistance of the ternary alloy is higher than that of the binary alloy. The most significant increase in electrical resistance of both the initially deformed and pre-hardened alloy Cu–8Pd–3Ag is observed after annealing for maximum duration at temperature of 250°C. X-ray diffraction patterns of samples after such heat treatment remain virtually unchanged.