Abstract
A simplified method of preparing solutions of glycerol and water for use in humidity control is described. The advantages of glycerol-water solutions over other solutions commonly used for humidity control in corrosion studies is discussed. Solutions of glycerol and water were prepared in various concentrations and their specific gravities determined. The percent relative humidity over each solution was measured and plotted against specific gravity of the solution. The resulting smooth curve can be used in preparing humidity control solutions accurate to within one unit of percent relative humidity. 2.3.1Keywords
This publication has 2 references indexed in Scilit:
- Control of Humidity with Potassium Hydroxide, Sulphuric Acid, or other SolutionsBulletin of Entomological Research, 1951
- THE MAINTENANCE OF HIGH ATMOSPHERIC HUMIDITIES FOR ENTOMOLOGICAL WORK WITH GLYCEROL‐WATER MIXTURESAnnals of Applied Biology, 1940