Abstract
The regional grid codes mandate that wind energy conversion systems (WECSs) stay connected during grid faults as long as terminal voltages stay above a specified level with respect to the fault duration. While existing low-voltage ride-through (LVRT) strategies for DFIG-WECSs satisfy these requirements, they do not guarantee maximum AC bus voltage recovery, which is essential for maintaining grid connectivity during severe faults. This paper presents an LVRT strategy for an on-grid DFIG supplying an AC microgrid. Rotor and stator overcurrent in the initial fault stage are limited using a crowbar. Then, a proposed coordinated RSC-GSC control aligns the DFIG-stator and transformer HV-side currents, maximizing the resultant AC bus injected current. Next, a modified adaptive voltage support scheme further maintains optimal real-time d-q current ratios for both converters (utilizing full capacity), so that overall injected current matches the network X/R ratio, ensuring maximum voltage recovery, regardless of the fault level, duration, location, wind speed, and wind farm condition. OPAL-RT real-time simulations confirm a 5.90% improvement in AC-bus voltage recovery and an 82% enhancement in post-fault transient response over recent literature.Keywords
This publication has 38 references indexed in Scilit:
- Influence of low-voltage ride-through control techniques on the thermal behavior of power converters applied to wind energy conversion systems based on the doubly-fed induction generatorElectric Power Systems Research, 2024
- A sensorless control strategy for automatic start‐up and grid‐synchronization of doubly fed induction generator in wind energy conversion systemInternational Journal of Circuit Theory and Applications, 2023
- A novel low voltage ride-through scheme for DFIG based on the cooperation of hybrid energy storage system and crowbar circuitJournal of Energy Storage, 2023
- Decoupled power-based sliding mode control modeling enhancement for dynamic stability in doubly-fed induction generator-based wind turbinesComputers and Electrical Engineering, 2022
- Fault characteristics analysis of DFIGWT in whole LVRT process considering control strategy switching between RSC and CrowbarInternational Journal of Electrical Power & Energy Systems, 2022
- Dynamic Voltage Restorer (DVR) with a novel robust control strategyISA Transactions, 2022
- LVRT capability enhancement in the grid-connected DFIG-driven WECS using adaptive hysteresis current controllerEnvironment, Development and Sustainability, 2021
- Analyzing low voltage ride through capability of doubly fed induction generator based wind turbineComputers and Electrical Engineering, 2020
- Modified rotor-side converter control design for improving the LVRT capability of a DFIG-based WECSElectric Power Systems Research, 2020
- Lagrange interpolating polynomial–based deloading control scheme for variable speed wind turbinesInternational Transactions on Electrical Energy Systems, 2019