An inkjet-printed polysaccharide matrix for on-chip sample preparation in point-of-care cell counting chambers
Open Access
- 12 May 2020
- journal article
- research article
- Published by Royal Society of Chemistry (RSC) in RSC Advances
- Vol. 10 (31) , 18062-18072
Abstract
On-chip sample preparation in self-contained microfluidic devices is a key element to realize simple, low-cost, yet reliable in vitro diagnostics that can be carried out at the point-of-care (POC) with minimal training requirements by unskilled users. To address this largely unmet POC medical need, we have developed an optimized polysaccharide matrix containing the reagents which substantially improves our fully printed POC CD4 counting chambers for the monitoring of HIV patients. The simply designed counting chambers allow for capillary-driven filling with unprocessed whole blood. We carefully tailored a gellan/trehalose matrix for deposition by inkjet printing, which preserves the viability of immunostains during a shelf life of at least 3 months and enables controlled antibody release for intense and homogeneous immunofluorescent cell staining throughout the complete 60 mm2 image area within 30 min. Excellent agreement between CD4 counts obtained from our fully printed CD4 counting chambers and the gold standard, flow cytometry, is demonstrated using samples both from healthy donors and HIV-infected patients.Keywords
Funding Information
- H2020 European Research Council (H2020-ERC-PoC-694045)
- FP7 Ideas: European Research Council (FP7-IDEAS-ERC-282276)
- FP7 People: Marie-Curie Actions (FP7-PEOPLE-2012-IEF-331131)
This publication has 50 references indexed in Scilit:
- Emerging technologies for point-of-care CD4 T-lymphocyte countingTrends in Biotechnology, 2012
- Controlled release of reagents in capillary-driven microfluidics using reagent integratorsLab on a Chip, 2011
- Controlled reagent transport in disposable 2D paper networksLab on a Chip, 2010
- Effect of trehalose on protein structureProtein Science, 2008
- Towards non- and minimally instrumented, microfluidics-based diagnostic devicesLab on a Chip, 2008
- Capillarity in microfluidic channels with hydrophilic and hydrophobic wallsMicrofluidics and Nanofluidics, 2008
- Monitoring patients with HIV diseaseJournal of Clinical Pathology, 2000
- Chemical stability of some model polysaccharidesMacromolecular Symposia, 1997
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986
- Renaturation of Aequorea green-fluorescent proteinBiochemical and Biophysical Research Communications, 1981