Elevation Changes of Central Posterior Corneal Surface After Intracorneal Ring Segment Implantation in Keratoconus
Authors:
- David P. PiñeroDavid P. Piñero
- Anil KubalogluAKAnil Kubaloglu
- Jorge L. AlioJorge L. Alio
- Yasin CinarYCYasin Cinar
- 1 April 2012
- journal article
- research article
- Published by Wolters Kluwer Health in Cornea
- Vol. 31 (4) , 387-395
Abstract
To compare changes that occur at the posterior corneal surface after the implantation of intracorneal ring segments (ICRSs) using either mechanical or femtosecond laser-assisted procedures and to correlate these changes with the visual outcome achieved. Retrospective, nonrandomized, and interventional case series including 223 consecutive eyes of 186 patients with keratoconus ranging in age from 16 to 39 years that were implanted with ring segments (KeraRing; Mediphacos) at Kartal Training and Research Hospital, Istanbul, Turkey. Two groups were created according to the surgical technique used: mechanical group (168 eyes) and femtosecond group (55 eyes). Visual and refractive outcomes and corneal elevation changes were evaluated during a 24-month follow-up. Correlations between visual and posterior elevation changes were evaluated. The posterior corneal surface could not be analyzed with accuracy for diameters larger than the diameter of the ICRS implant. A statistically significant reduction of maximum elevation for both the corneal surfaces was observed at 1 month after the surgery (P < 0.01), with additional reductions at 3 and 6 months (P ≤ 0.03). In addition, the posterior best-fit sphere was flattened significantly at 1 month after the surgery in both the groups, with additional flattening at 3 months (P ≤ 0.03). No significant differences between groups in posterior corneal elevation parameters were found at any time point of the follow-up (P ≥ 0.14). Moderate and significant correlations of the postoperative visual outcome with the change in posterior best-fit sphere were found only in the femtosecond group. A central corneal flattening of the posterior corneal surface occurs after ring segment implantation in keratoconus.Keywords
This publication has 25 references indexed in Scilit:
- Modeling the Intracorneal Ring Segment Effect in Keratoconus Using Refractive, Keratometric, and Corneal Aberrometric DataInvestigative Ophthalmology & Visual Science, 2010
- Corneal volume, pachymetry, and correlation of anterior and posterior corneal shape in subclinical and different stages of clinical keratoconusJournal of Cataract & Refractive Surgery, 2010
- Keratoconus in the Medicare PopulationCornea, 2009
- Keratoconus Diagnosis with Optical Coherence Tomography Pachymetry MappingOphthalmology, 2008
- Longitudinal analysis of corneal topography in suspected keratoconusBritish Journal of Ophthalmology, 2008
- Comparison of and correlation between anterior and posterior corneal elevation maps in normal eyes and keratoconus-suspect eyesJournal of Cataract & Refractive Surgery, 2008
- Anterior segment biometry with the Pentacam: Comprehensive assessment of repeatability of automated measurementsJournal of Cataract & Refractive Surgery, 2008
- A New Method for Grading the Severity of KeratoconusCornea, 2006
- Intracorneal ring segments for keratoconus correction: Long-term follow-upJournal of Cataract & Refractive Surgery, 2006
- Analysis of results related to good and bad outcomes of Intacs implantation for keratoconus correctionJournal of Cataract & Refractive Surgery, 2006